Cs2ZrCl6 scintillation properties studied using γ-ray spectroscopy and Compton coincidence technique
Bibliographic record
Abstract
The scintillation properties of cesium-zirconium hexachloride (Cs2ZrCl6) were investigated by γ-ray spectrometry and the Compton Coincidence Technique. The tested cylindrical sample had 20 mm diameter and 12 mm height. The crystal shows a high light output of 40 900 photons per MeV as measured by a spectroscopy type photomultiplier with 20 μs pulse integration time under γ-ray excitation at room temperature. A small deviation from linear response as a function of energy deposited in γ-ray absorption or Compton scattering processes, combined with a high light yield, results in good energy resolution equal to 4.3 % at 662 keV and 2.3 % at 2.6 MeV. Due to long lasting scintillation decay the sample properties were studied at different shaping time constants in an analogue spectroscopy chain or using different integration time gates when employing a digital analyzer.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.002 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".