MétaCan
Menu
Back to cohort
Record W4388015392 · doi:10.5694/mja2.52151

<scp>COVID</scp>‐19 rapid antigen tests approved for self‐testing in Australia: published diagnostic test accuracy studies and manufacturer‐supplied information. A systematic review

2023· review· en· W4388015392 on OpenAlexaboutno aff
Katy Bell, Yuyang Li, Ellie Medcalf, Deonna Ackermann

Bibliographic record

VenueThe Medical Journal of Australia · 2023
Typereview
Languageen
FieldMedicine
TopicSARS-CoV-2 detection and testing
Canadian institutionsnot available
FundersNational Health and Medical Research CouncilUniversity of SydneyCancer Institute NSW
KeywordsMedicineTest (biology)AmbulatoryCoronavirus disease 2019 (COVID-19)Diagnostic testFamily medicineHealth careSevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2)Emergency medicineInternal medicineDiseaseInfectious disease (medical specialty)

Abstract

fetched live from OpenAlex

OBJECTIVES: To review evaluations of the diagnostic accuracy of coronavirus disease 2019 (COVID-19) rapid antigen tests (RATs) approved by the Therapeutic Goods Administration (TGA) for self-testing by ambulatory people in Australia; to compare these estimates with values reported by test manufacturers. STUDY DESIGN: Systematic review of publications in any language that reported cross-sectional, case-control, or cohort studies in which the participants were ambulatory people in the community or health care workers in hospitals in whom severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection was suspected, and the results of testing self-collected biological samples with a TGA-approved COVID-19 RAT were compared with those of reverse transcription-polymerase chain reaction (RT-PCR) testing for SARS-CoV-2. Estimates of diagnostic accuracy (sensitivity, specificity) were checked and compared with manufacturer estimates published on the TGA website. DATA SOURCES: Publications (to 1 September 2022) identified in the Cochrane COVID-19 Study Register and the World Health Organization COVID-19 research database. Information on manufacturer diagnostic accuracy evaluations was obtained from the TGA website. DATA SYNTHESIS: Twelve publications that reported a total of eighteen evaluations of eight RATs approved by the TGA for self-testing (manufacturers: All Test, Roche, Flowflex, MP Biomedicals, Clungene, Panbio, V-Chek, Whistling) were identified. Five studies were undertaken in the Netherlands, two each in Germany and the United States, and one each in Denmark, Belgium, and Canada; test sample collection was unsupervised in twelve studies, and supervised by health care workers or researchers in six. Estimated sensitivity with unsupervised sample collection ranged from 20.9% (MP Biomedicals) to 74.3% (Roche), and with supervised collection from 7.7% (V-Chek) to 84.4% (Panbio); the estimates were between 8.2 and 88 percentage points lower than the values reported by the manufacturers. Test specificity was high for all RATs (97.9-100%). CONCLUSIONS: The risk of false negative results when using COVID-19 RATs for self-testing may be considerably higher than apparent in manufacturer reports on the TGA website, with implications for the reliability of these tests for ruling out infection.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.018
metaresearch head score (Gemma)0.119
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.018
Threshold uncertainty score0.093

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0180.119
Meta-epidemiology (narrow)0.0020.002
Meta-epidemiology (broad)0.0100.008
Bibliometrics0.0170.017
Science and technology studies0.0010.001
Scholarly communication0.0030.004
Open science0.0020.002
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0100.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.198
GPT teacher head0.433
Teacher spread0.236 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueThe Medical Journal of AustraliaSame topicSARS-CoV-2 detection and testingFrench-language works237,207