MétaCan
Menu
Back to cohort
Record W4388289577 · doi:10.3389/fneur.2023.1255620

Feasibility and safety study of wearable cyborg Hybrid Assistive Limb for pediatric patients with cerebral palsy and spinal cord disorders

2023· article· en· W4388289577 on OpenAlexaboutno aff
Kazushi Takahashi, Masafumi Mizukami, Mayumi Matsuda Kuroda, Yukiyo Shimizu, Takashi Nakajima, Hirotaka Mutsuzaki, Hiroshi Kamada, Kayo Tokeji, Yasushi Hada, Kazunori Koseki, Kenichi Yoshikawa, Tomohiro Nakayama, Nobuaki Iwasaki, Hiroaki Kawamoto, Yoshiyuki Sankai, Masashi Yamazaki, Akira Matsumura, Aiki Marushima

Bibliographic record

VenueFrontiers in Neurology · 2023
Typearticle
Languageen
FieldEngineering
TopicProsthetics and Rehabilitation Robotics
Canadian institutionsnot available
FundersCenter for Innovative MedicineUniversity of TsukubaJapan Agency for Medical Research and Development
KeywordsCerebral palsyWilcoxon signed-rank testMedicinePhysical medicine and rehabilitationSpinal cord injuryPhysical therapyAdverse effectMotor functionPsychologySpinal cordInternal medicine

Abstract

fetched live from OpenAlex

Introduction The wearable cyborg Hybrid Assistive Limb (HAL) is the world’s first cyborg-type wearable robotic device, and it assists the user’s voluntary movements and facilitates muscle activities. However, since the minimum height required for using the HAL is 150 cm, a smaller HAL (2S size) has been newly developed for pediatric use. This study aimed to (1) examine the feasibility and safety of a protocol for treatments with HAL (2S size) in pediatric patients and (2) explore the optimal method for assessing the efficacy of HAL. Methods This clinical study included seven pediatric patients with postural and motor function disorders, who received 8–12 sessions of smaller HAL (2S size) treatment. The primary outcome was the Gross Motor Function Measure-88 (GMFM-88). The secondary outcomes were GMFM-66, 10-m walk test, 2- and 6-min walking distances, Canadian Occupational Performance Measure (COPM), a post-treatment questionnaire, adverse events, and device failures. Statistical analyses were performed using the paired samples t -test or Wilcoxon signed-rank test. Results All participants completed the study protocol with no serious adverse events. GMFM-88 improved from 65.51 ± 21.97 to 66.72 ± 22.28 ( p = 0.07). The improvements in the secondary outcomes were as follows: GMFM-66, 53.63 ± 11.94 to 54.96 ± 12.31, p = 0.04; step length, 0.32 ± 0.16 to 0.34 ± 0.16, p = 0.25; 2-MWD, 59.1 ± 57.0 to 62.8 ± 63.3, p = 0.54; COPM performance score, 3.7 ± 2.0 to 5.3 ± 1.9, p = 0.06; COPM satisfaction score, 3.3 ± 2.1 to 5.1 ± 2.1, p = 0.04. Discussion In this exploratory study, we applied a new size of wearable cyborg HAL (2S size), to children with central nervous system disorders. We evaluated its safety, feasibility, and identified an optimal assessment method for multiple treatments. All participants completed the protocol with no serious adverse events. This study suggested that the GMFM would be an optimal assessment tool for validation trials of HAL (2S size) treatment in pediatric patients with posture and motor function disorders.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.009
Threshold uncertainty score0.370

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.222
Teacher spread0.214 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueFrontiers in NeurologySame topicProsthetics and Rehabilitation RoboticsFrench-language works237,207