MétaCan
Menu
Back to cohort
Record W4388657059 · doi:10.1111/aor.14676

Safety and performance of the Clearum™ high flux hemodialyzer

2023· article· en· W4388657059 on OpenAlexaff
Thilo Krüger, Frank Dellanna, Werner Kleophas, Ons Flader, Candace K. McClure, Marialuisa Caiazzo, Silvia Manfredini

Bibliographic record

VenueArtificial Organs · 2023
Typearticle
Languageen
FieldMedicine
TopicDialysis and Renal Disease Management
Canadian institutionsBell (Canada)
Fundersnot available
KeywordsHemodialysisMedicineSurgeryChemistry

Abstract

fetched live from OpenAlex

BACKGROUND: Clearum™ is a high flux steam sterilized dialyzer for patients with hemodialysis or hemodiafiltration. This study evaluated the safety and performance of the Clearum high flux steam sterilized hemodialyzer in the removal of small and middle-sized toxins. METHODS: A prospective, interventional, nonrandomized study enrolled twenty end-stage renal disease patients undergoing hemodialysis. The Clearum high flux steam sterilized dialyzer was compared to Fresenius FX dialyzers for baseline comparison. The duration of the trial was 2 weeks for the FX dialyzer and 6 weeks with the Clearum high flux steam sterilized dialyzer. In vitro studies with dextrans of varying sizes were performed to compare the membrane characteristics and sieving coefficient curves for the two dialyzers. RESULTS: The primary objective of a mean urea reduction ratio >65% was met, with no significant difference in mean urea reduction ratio between the Clearum high flux steam sterilized and Fresenius FX-series of dialyzers (p = 0.86). No dialyzer-related adverse events were reported in the study. β-2-microglobulin reduction with the Clearum high flux steam sterilized dialyzer was statistically higher than the FX-series dialyzer (66.5% vs. 53.6%; p < 0.0001). Predialysis interleukin-6 and C-reactive protein concentrations, blood-rest scores (residual blood after blood restitution), and thrombin-anti-thrombin values were comparable. Albumin remained stable during the 6 weeks of Clearum high flux steam sterilized dialyzer use, with no appreciable differences compared to the Fresenius FX-series. CONCLUSION: The Clearum high flux steam sterilized dialyzer showed good mid-term effectivity for small and middle molecule removal with no reported dialyzer-related adverse events.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.638
Threshold uncertainty score0.268

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.228
Teacher spread0.216 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueArtificial OrgansSame topicDialysis and Renal Disease ManagementFrench-language works237,207