MétaCan
Menu
Back to cohort
Record W4388775695 · doi:10.2478/pjmpe-2023-0020

Dosimetric evaluation of VMAT automated breast treatment plans: Towards the establishment of an institutional plan acceptability criteria

2023· article· en· W4388775695 on OpenAlexaff
George Felix Acquah, Francis Hasford, Samuel Nii Adu Tagoe, A. Diakité, Victor Adjenou, Ernest Osei

Bibliographic record

VenuePolish Journal of Medical Physics And Engineering · 2023
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsGrand River HospitalUniversity of Waterloo
Fundersnot available
KeywordsMedicineNuclear medicineContouringBreast cancerLeft breastRadiation treatment planningRadiologyRadiation therapyCancerInternal medicine

Abstract

fetched live from OpenAlex

Abstract Introduction: To evaluate the clinical suitability of the current facility-based treatment plan protocol in establishing acceptability criteria. Material and methods: Automated Volumetric Arc Therapy (VMAT) treatment plans were retrospectively evaluated for intact breast and chest-wall cancer patients from January 2021 to January 2023. Results: A total of 94 patients were planned and treated using automated contouring and VMAT planning technique. The number of patients planned and treated for intact breast and chest-wall were 41 (43.6%) and 53 (56.4%), respectively. The mean intact breast volumes for optimization (Brst_opt) receiving 95% and 105% of the prescribed doses were 92.80% ± 1.11 and 1.54% ± 1.02, respectively. Their corresponding mean chest-wall volumes for optimization (Chst_opt) were 90.65% ± 3.19 and 2.28% ± 2.99, respectively. For left-sided cases, the mean heart dose received was 4.61 Gy ± 1.76 and 5.18 Gy ± 1.55 for intact breast plans and that for chest-wall plans, respectively. The mean ipsilateral lung volume receiving 20 Gy of the prescribed dose was 12.22% ± 3.86 and 13.19% ± 3.74 for intact breast plans and chest-wall plans, respectively. For the Brst_opt and Chst_opt dose metrics were calculated; the mean homogeneity index (HI) was 0.14 ± 0.03 and 0.15 ± 0.04, mean uniformity index (UI) was 1.09 ± 0.03 and 1.11 ± 0.03, and mean conformity index (CI) were 0.92 ± 0.04 and 0.91 ± 0.04, respectively. Conclusions: The dosimetric evaluation shows a good dose distribution in the target volumes with minimal doses to the organs at risk (OAR). Assessment of the current data affirms the clinical usefulness of the facility-adopted protocol in achieving quality treatment plans for intact breast and chest-wall irradiations. The establishment of plan acceptability criteria will help achieve improved overall treatment outcomes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.009
metaresearch head score (Gemma)0.021
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.009
Threshold uncertainty score0.050

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0090.021
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.336
Teacher spread0.304 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more

Same venuePolish Journal of Medical Physics And EngineeringSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207