MétaCan
Menu
Back to cohort
Record W4388776931 · doi:10.1097/lbr.0000000000000948

Defining Optimal Settings for Lung Cryobiopsy in End-Stage Pulmonary Disease. A Human, Ex Vivo, Diseased Lung Clinical Trial

2023· article· en· W4388776931 on OpenAlexaff
Vanessa Menezes, Clare Pollock, Pasquale Ferraro, Basil Nasir, Charles Leduc, Julie Morisset, Moïshe Liberman

Bibliographic record

VenueJournal of Bronchology & Interventional Pulmonology · 2023
Typearticle
Languageen
FieldMedicine
TopicInterstitial Lung Diseases and Idiopathic Pulmonary Fibrosis
Canadian institutionsCentre Hospitalier de l’Université de Montréal
Fundersnot available
KeywordsMedicineLung transplantationLungBronchoscopyEx vivoBiopsyTransplantationHistologyRadiologyPathologyParenchymaStage (stratigraphy)Nuclear medicineIn vivoSurgeryInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: To evaluate optimal settings of probe size, freezing time, and distance to the pleura that influence the size and quality of biopsy specimens during transbronchial lung cryobiopsies in ESPD. METHODS: We prospectively recruited 17 patients undergoing lung transplantation. We created a nonperfused ex vivo bronchoscopy setting to perform multiple cryobiopsies with different probe sizes (1.7, 1.9, and 2.4 mm), freezing times (3, 5, 7, 10, 20, 30 seconds), and probe distance from pleura (5, 10, and 20 mm). Alveolated pulmonary parenchyma area≥50% in histology was considered a good quality biopsy, with a minimum procedural artifact. We used logistic regression to identify independent parameters as risk factors for histologic adequacy. RESULTS: A total of 545 cryobiopsies were obtained from 34 explanted lungs after pneumonectomy for lung transplantation. The mean maximum diameter of the specimen achieved with the 1.7 probe was larger (13.5 mm) than those obtained with 1.9 and 2.4 mm probes (11.3 and 10.7 mm, P= 0.07). More pleural macroscopic damage and pleural tissue in histology occurred with the 2.4 mm probe ( P <0.001). There was no difference in the quality of specimens between the different freezing times and the distance from the pleura. CONCLUSIONS: Freezing time and distance from the pleura did not affect the histologic quality for diagnosing ESPD in severely damaged lungs. Smaller cryoprobe size did not negatively affect sample adequacy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.571
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.002
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.036
GPT teacher head0.391
Teacher spread0.355 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more