MétaCan
Menu
Back to cohort
Record W4388916519 · doi:10.2196/51921

Designing Human-Centered AI to Prevent Medication Dispensing Errors: Focus Group Study With Pharmacists

2023· article· en· W4388916519 on OpenAlexvenueno aff
Yifan Zheng, Brigid Rowell, Qiyuan Chen, Jin Yong Kim, Raed Al Kontar, X. Jessie Yang, Corey A. Lester

Bibliographic record

VenueJMIR Formative Research · 2023
Typearticle
Languageen
FieldHealth Professions
TopicElectronic Health Records Systems
Canadian institutionsnot available
FundersU.S. National Library of MedicineNational Institutes of Health
KeywordsFocus groupBrainstormingComputer scienceMultidisciplinary approachPharmacyInterface (matter)Session (web analytics)Patient safetyFocus (optics)Artificial intelligenceMedicineHealth careNursingWorld Wide Web

Abstract

fetched live from OpenAlex

BACKGROUND: Medication errors, including dispensing errors, represent a substantial worldwide health risk with significant implications in terms of morbidity, mortality, and financial costs. Although pharmacists use methods like barcode scanning and double-checking for dispensing verification, these measures exhibit limitations. The application of artificial intelligence (AI) in pharmacy verification emerges as a potential solution, offering precision, rapid data analysis, and the ability to recognize medications through computer vision. For AI to be embraced, it must be designed with the end user in mind, fostering trust, clear communication, and seamless collaboration between AI and pharmacists. OBJECTIVE: This study aimed to gather pharmacists' feedback in a focus group setting to help inform the initial design of the user interface and iterative designs of the AI prototype. METHODS: A multidisciplinary research team engaged pharmacists in a 3-stage process to develop a human-centered AI system for medication dispensing verification. To design the AI model, we used a Bayesian neural network that predicts the dispensed pills' National Drug Code (NDC). Discussion scripts regarding how to design the system and feedback in focus groups were collected through audio recordings and professionally transcribed, followed by a content analysis guided by the Systems Engineering Initiative for Patient Safety and Human-Machine Teaming theoretical frameworks. RESULTS: A total of 8 pharmacists participated in 3 rounds of focus groups to identify current challenges in medication dispensing verification, brainstorm solutions, and provide feedback on our AI prototype. Participants considered several teaming scenarios, generally favoring a hybrid teaming model where the AI assists in the verification process and a pharmacist intervenes based on medication risk level and the AI's confidence level. Pharmacists highlighted the need for improving the interpretability of AI systems, such as adding stepwise checkmarks, probability scores, and details about drugs the AI model frequently confuses with the target drug. Pharmacists emphasized the need for simplicity and accessibility. They favored displaying only essential information to prevent overwhelming users with excessive data. Specific design features, such as juxtaposing pill images with their packaging for quick comparisons, were requested. Pharmacists preferred accept, reject, or unsure options. The final prototype interface included (1) checkmarks to compare pill characteristics between the AI-predicted NDC and the prescription's expected NDC, (2) a histogram showing predicted probabilities for the AI-identified NDC, (3) an image of an AI-provided "confused" pill, and (4) an NDC match status (ie, match, unmatched, or unsure). CONCLUSIONS: In partnership with pharmacists, we developed a human-centered AI prototype designed to enhance AI interpretability and foster trust. This initiative emphasized human-machine collaboration and positioned AI as an augmentative tool rather than a replacement. This study highlights the process of designing a human-centered AI for dispensing verification, emphasizing its interpretability, confidence visualization, and collaborative human-machine teaming styles.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.012
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesScience and technology studies, Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Qualitative · Consensus signal: Qualitative
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.235
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0120.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.002
Science and technology studies0.0030.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.002
Insufficient payload (model declined to judge)0.0000.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.252
GPT teacher head0.592
Teacher spread0.340 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designQualitative
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations29
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueJMIR Formative ResearchSame topicElectronic Health Records SystemsFrench-language works237,207