MétaCan
Menu
Back to cohort
Record W4388922012 · doi:10.1111/jce.16123

High‐power short‐duration versus low‐power long‐duration ablation for pulmonary vein isolation: A substudy of the AWARE randomized controlled trial

2023· article· en· W4388922012 on OpenAlexafffund
Jacqueline Joza, Girish M. Nair, David H. Birnie, Pablo B. Nery, Calum J. Redpath, J. Sarrazin, Jean Champagne, Jordan Bernick, George A. Wells, Vidal Essebag

Bibliographic record

VenueJournal of Cardiovascular Electrophysiology · 2023
Typearticle
Languageen
FieldMedicine
TopicAtrial Fibrillation Management and Outcomes
Canadian institutionsHôpital du Sacré-Cœur de MontréalCentre de Développement du Porc du QuébecInstitut universitaire de cardiologie et de pneumologie de QuébecUniversity of OttawaMcGill UniversityMcGill University Health Centre
FundersBiosense WebsterFonds de Recherche du Québec - SantéCanadian Institutes of Health ResearchBoston Scientific CorporationServierPfizerUniversity of OttawaMedtronicBristol-Myers Squibb
KeywordsMedicineAtrial fibrillationPulmonary veinConfidence intervalInternal medicineClinical endpointCardiologyRandomized controlled trialNuclear medicine

Abstract

fetched live from OpenAlex

Abstract Introduction Pulmonary vein isolations (PVI) are being performed using a high‐power, short‐duration (HPSD) strategy. The purpose of this study was to compare the clinical efficacy and safety outcomes of an HPSD versus low‐power, long‐duration (LPLD) approach to PVI in patients with paroxysmal atrial fibrillation (AF). Methods Patients were grouped according to a HPSD (≥40 W) or LPLD (≤35 W) strategy. The primary endpoint was the 1‐year recurrence of any atrial arrhythmia lasting ≥30 s, detected using three 14‐day ambulatory continuous ECG monitoring. Procedural and safety endpoints were also evaluated. The primary analysis were regression models incorporating propensity scores yielding adjusted relative risk (RR a ) and mean difference (MD a ) estimates. Results Of the 398 patients included in the AWARE Trial, 173 (43%) underwent HPSD and 225 (57%) LPLD ablation. The distribution of power was 50 W in 75%, 45 W in 20%, and 40 W in 5% in the HPSD group, and 35 W with 25 W on the posterior wall in the LPLD group. The primary outcome was not statistically significant at 30.1% versus 22.2% in HPSD and LPLD groups with RR a 0.77 (95% confidence interval [CI]) 0.55–1.10; p = .165). The secondary outcome of repeat catheter ablation was not statistically significant at 6.9% and 9.8% (RR a 1.59 [95% CI 0.77–3.30]; p = .208) respectively, nor was the incidence of any ECG documented AF during the blanking period: 1.7% versus 8.0% (RR a 3.95 [95% CI 1.00–15.61; p = .049) in the HPSD versus LPLD group respectively. The total procedure time was significantly shorter in the HPSD group (MD a 97.5 min [95% CI 84.8–110.4)]; p < .0001) with no difference in adjudicated serious adverse events. Conclusions An HPSD strategy was associated with significantly shorter procedural times with similar efficacy in terms of clinical arrhythmia recurrence. Importantly, there was no signal for increased harm with a HPSD strategy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.025
Threshold uncertainty score0.534

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0020.004
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.290
Teacher spread0.269 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Cardiovascular ElectrophysiologySame topicAtrial Fibrillation Management and OutcomesFrench-language works237,207