MétaCan
Menu
Back to cohort
Record W4389179839 · doi:10.1051/sicotj/2023033

Estimated diameter increase from a 4S to a 6S hamstring graft configuration – A cadaveric study

2023· article· en· W4389179839 on OpenAlexaff
Yoan Bourgeault‐Gagnon, Alexandre Keith Leang, Sonia Bédard, Karina Lebel, Frédéric Balg, François Vézina

Bibliographic record

VenueSICOT-J · 2023
Typearticle
Languageen
FieldMedicine
TopicKnee injuries and reconstruction techniques
Canadian institutionsCentre Intégré Universitaire de Santé et de Services Sociaux du Centre-Sud-de-l'Île-de-MontréalCégep de Sorel-TracyCentres Intégré Universitaires de Santé et de Services SociauxCentre Intégré Universitaire de Santé et de Services Sociaux du Saguenay–Lac-Saint-JeanHôtel-Dieu de QuébecCentre Hospitalier Universitaire de SherbrookeUniversité de Sherbrooke
Fundersnot available
KeywordsCadaveric spasmHamstringPopulationBiomedical engineeringSurgeryMaterials scienceMedicine

Abstract

fetched live from OpenAlex

PURPOSE: Graft diameter in anterior cruciate ligament reconstructions has been shown to influence the risk of failure. It is therefore important to be able to adjust the graft configuration to modify the diameter. To measure the impact of a 6-strand (6S) hamstring autograft configuration on graft diameter compared to the standard 4-strand (4S) configuration. METHODS: Cadaveric study on 33 knees, using the usual hamstring graft harvesting technique. Semitendinosus and gracilis tendons were harvested and their length, width, and diameter were measured in 4S and 6S configurations separately by three evaluators. RESULTS: 6S configuration leads to a median increase of 1.5 (range: 0.0-2.0) mm in diameter compared to 4S (p < 0.001). A graft diameter of more than 8 mm is attained in less than a third of 4S grafts within this population in comparison to 84% when the 6S configuration is used. DISCUSSION: The 6S hamstring graft configuration increases the graft diameter by a median of 1.5 millimeters compared to the traditional 4S configuration. It can reliably be used to obtain an 8.5 mm graft diameter or more in cases where the semitendinosus measures at least 270.5 mm and the 4S configuration has a diameter of 7.5 mm or 8 mm. This information helps to better delineate the impact of a 6S configuration in a pre-operative or intra-operative setting to optimize the decisional process and surgical flow and to easily adapt the graft diameter. LEVEL OF EVIDENCE: V (cadaveric study).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.031
GPT teacher head0.326
Teacher spread0.295 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueSICOT-JSame topicKnee injuries and reconstruction techniquesFrench-language works237,207