MétaCan
Menu
Back to cohort
Record W4389297095 · doi:10.1007/s00216-023-05053-3

Comparison of calibration strategies for accurate quantitation by isotope dilution mass spectrometry: a case study of ochratoxin A in flour

2023· article· en· W4389297095 on OpenAlexafffund
Jennifer Bates, Adilah Bahadoor, Sheryl A. Tittlemier, Jeremy E. Melanson

Bibliographic record

VenueAnalytical and Bioanalytical Chemistry · 2023
Typearticle
Languageen
FieldAgricultural and Biological Sciences
TopicMycotoxins in Agriculture and Food
Canadian institutionsNational Research Council Canada
FundersNational Research Council Canada
KeywordsIsotope dilutionChromatographyChemistryMass spectrometryAnalytical Chemistry (journal)CalibrationCertified reference materialsMatrix (chemical analysis)DilutionSample preparationOchratoxin ADetection limitMathematicsMycotoxinFood science

Abstract

fetched live from OpenAlex

Abstract Analysis of low-level organic contaminants in complex matrices is essential for monitoring global food safety. However, balancing sample throughput with complex experimental designs and/or sample clean-up to best reduce matrix effects is a constant challenge. Multiple strategies exist to mitigate these effects, with internal standard-based methods such as isotope dilution mass spectrometry (IDMS) being the most advantageous. Here, multiple internal calibration strategies were investigated for the quantification of ochratoxin A (OTA) in wheat samples by liquid chromatography-mass spectrometry (LC-MS). Internal standard-based quantitation methods such as single (ID 1 MS), double (ID 2 MS), and quintuple (ID 5 MS) isotope dilution mass spectrometry, as well as external standard calibration, were explored and compared. A certified reference material (CRM) of OTA in flour, MYCO-1, was used to evaluate the accuracy of each method. External calibration generated results 18–38% lower than the certified value for MYCO-1, largely due to matrix suppression effects. Concurrently, consistently lower OTA mass fractions were obtained for the wheat samples upon quantitation by external calibration as opposed to ID 1 MS, ID 2 MS, and ID 5 MS. All isotope dilution methods produced results that fell within the expected range for MYCO-1 (3.17–4.93 µg/kg), validating their accuracy. However, an average 6% decrease in the OTA mass fraction was observed from results obtained by ID 1 MS compared to those by ID 2 MS and ID 5 MS. Upon scrutiny, these differences were attributed to an isotopic enrichment bias in the isotopically labelled internal standard [ 13 C 6 ]-OTA that was used for ID 1 MS, the OTAL-1 CRM. The advantages and limitations of each isotopic method are illustrated.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.676
Threshold uncertainty score0.272

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.048
GPT teacher head0.327
Teacher spread0.279 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueAnalytical and Bioanalytical ChemistrySame topicMycotoxins in Agriculture and FoodFrench-language works237,207