MétaCan
Menu
Back to cohort
Record W4389384030 · doi:10.1021/acs.analchem.3c02924

Current Practices in LC-MS Untargeted Metabolomics: A Scoping Review on the Use of Pooled Quality Control Samples

2023· review· en· W4389384030 on OpenAlexafffund
Corey D. Broeckling, Richard D. Beger, Leo L. Cheng, Raquel Cumeras, Daniel J. Cuthbertson, Surendra Dasari, William C. Davis, Warwick B. Dunn, Anne M. Evans, Álvaro Fernández‐Ochoa, Helen Gika, Royston Goodacre, Kelli D. Goodman, Gonçalo J. Gouveia, Ping-Ching Hsu, Jennifer Kirwan, Dritan Kodra, Julia Kuligowski, Renny S. Lan, Marı́a Eugenia Monge, Laura Moussa, Sindhu Nair, Nichole Reisdorph, Stacy D. Sherrod, Candice Ulmer Holland, Dajana Vuckovic, Li‐Rong Yu, Bo Zhang, Georgios Theodoridis, Jonathan D. Mosley

Bibliographic record

VenueAnalytical Chemistry · 2023
Typereview
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicMetabolomics and Mass Spectrometry Studies
Canadian institutionsConcordia UniversityUniversity of Alberta
FundersHORIZON EUROPE Marie Sklodowska-Curie ActionsNational Cancer InstituteNational Institute on AgingAgencia Estatal de InvestigaciónEuropean Regional Development FundInstituto de Salud Carlos IIIMedical Research CouncilFonds de Recherche du Québec - SantéNatural Sciences and Engineering Research Council of CanadaAgència de Gestió d'Ajuts Universitaris i de RecercaMinisterio de Asuntos Económicos y Transformación Digital, Gobierno de EspañaAgencia Nacional de Promoción Científica y TecnológicaConsejo Nacional de Investigaciones Científicas y TécnicasNational Institute of Neurological Disorders and StrokeBundesministerium für Bildung und ForschungFoundation for Chemistry Research and Initiatives
KeywordsMetabolomicsSample (material)Data qualityQuality (philosophy)Sample size determinationData miningChemistryComputer scienceComputational biologyStatisticsChromatographyMetric (unit)MathematicsBiologyEngineering

Abstract

fetched live from OpenAlex

Untargeted metabolomics is an analytical approach with numerous applications serving as an effective metabolic phenotyping platform to characterize small molecules within a biological system. Data quality can be challenging to evaluate and demonstrate in metabolomics experiments. This has driven the use of pooled quality control (QC) samples for monitoring and, if necessary, correcting for analytical variance introduced during sample preparation and data acquisition stages. Described herein is a scoping literature review detailing the use of pooled QC samples in published untargeted liquid chromatography-mass spectrometry (LC-MS) based metabolomics studies. A literature query was performed, the list of papers was filtered, and suitable articles were randomly sampled. In total, 109 papers were each reviewed by at least five reviewers, answering predefined questions surrounding the use of pooled quality control samples. The results of the review indicate that use of pooled QC samples has been relatively widely adopted by the metabolomics community and that it is used at a similar frequency across biological taxa and sample types in both small- and large-scale studies. However, while many studies generated and analyzed pooled QC samples, relatively few reported the use of pooled QC samples to improve data quality. This demonstrates a clear opportunity for the field to more frequently utilize pooled QC samples for quality reporting, feature filtering, analytical drift correction, and metabolite annotation. Additionally, our survey approach enabled us to assess the ambiguity in the reporting of the methods used to describe the generation and use of pooled QC samples. This analysis indicates that many details of the QC framework are missing or unclear, limiting the reader's ability to determine which QC steps have been taken. Collectively, these results capture the current state of pooled QC sample usage and highlight existing strengths and deficiencies as they are applied in untargeted LC-MS metabolomics.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.013
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch, Meta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.875
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.013
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0030.001
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.268
GPT teacher head0.446
Teacher spread0.179 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations98
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicMetabolomics and Mass Spectrometry StudiesFrench-language works237,207