MétaCan
Menu
Back to cohort
Record W4389401403 · doi:10.46292/sci23-1985185s

Student Competition (Knowledge Generation) ID 1985185

2023· article· en· W4389401403 on OpenAlexafffund
Sisuri G. Hemakumara, Zahra Karamzadeh, Darren J. Mann, Trevor S. Barss, Vivian K. Mushahwar

Bibliographic record

VenueTopics in Spinal Cord Injury Rehabilitation · 2023
Typearticle
Languageen
FieldMedicine
TopicMusculoskeletal pain and rehabilitation
Canadian institutionsWomen and Children’s Health Research InstituteUniversity of Alberta
FundersCanadian Institutes of Health ResearchAlberta InnovatesCraig H. Neilsen Foundation
KeywordsMedicineWhiplashTibialis anterior muscleH-reflexReflexEvoked potentialPhysical medicine and rehabilitationSpinal cordStimulationElectrophysiologyElectromyographyAnesthesiaAudiologyNeurosciencePhysical therapyInternal medicinePsychologyPoison controlSkeletal muscle

Abstract

fetched live from OpenAlex

Background/Objective Transcutaneous spinal cord stimulation (tSCS) facilitates spinal networks involving motor function. The purpose of this study is to compare the effect of stimulators used and amplitude of tSCS, applied at the cervical region of the spinal cord, on propriospinal modulation of lower limbs. Corticospinal and spinal reflex excitability were assessed with lower limb motor evoked potentials (MEPs), and Hoffman (H-) reflexes, respectively. Methods Neurologically intact participants (n=6) were recruited. Two stimulators (NeoStim-5 and DS8R) were used, and different tSCS amplitudes at threshold (thresh) and maximum tolerance (max) were applied. The effect of tSCS on the amplitude of the H-reflex evoked in the soleus muscle was assessed, as well as the effect of cervical tSCS on MEPs evoked in the tibialis anterior muscle. Participants completed five conditions including: 1) Control (no stimulation) 2) DS8R Thresh 3) DS8R Max 4) NeoStim-5 Thresh 5) NeoStim-5 Max. Results At the same tSCS amplitude, the participants subjectively tolerated the NeoStim-5 better than the DS8R. The maximum tolerated amplitude for NeoStim-5 was higher than that of the DS8R, for all participants. Preliminary analysis suggests changes in tSCS amplitude delivered, do not appear to have an effect on the H-reflex and MEP in this small sample of participants. Conclusions Preliminary findings indicate that different stimulators produce different sensations at the same tSCS amplitudes. Changes in stimulator amplitudes do not appear to have an effect on the electrophysiological outcome on propriospinal modulation. This study sets the basis for understanding mechanisms of tSCS, including cutaneous activation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesInsufficient payload (model declined to judge)
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Other · Consensus signal: Other
Teacher disagreement score0.104
Threshold uncertainty score0.149

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0030.001
Open science0.0010.004
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.8960.791

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.388
Teacher spread0.353 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; the direct Gemma label and the distilled Codex classifier agree on what is shown here.

Study designNot applicable
Domainnot available
GenreOther

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueTopics in Spinal Cord Injury RehabilitationSame topicMusculoskeletal pain and rehabilitationFrench-language works237,207