MétaCan
Menu
Back to cohort
Record W4389655764 · doi:10.1093/eurheartj/ehad828

Residual leaks following percutaneous left atrial appendage occlusion and outcomes: a meta-analysis

2023· article· en· W4389655764 on OpenAlexaff
Athanasios Samaras, Αndreas S. Papazoglou, Charalampos Balomenakis, Αlexandra Bekiaridou, Dimitrios V. Moysidis, Vasiliki Patsiou, Antonios Orfanidis, George Giannakoulas, George Kassimis, Nikolaos Fragakis, Jacqueline Saw, Ulf Landmesser, Mohamad Adnan Alkhouli, Apostolos Tzikas

Bibliographic record

VenueEuropean Heart Journal · 2023
Typearticle
Languageen
FieldMedicine
TopicAtrial Fibrillation Management and Outcomes
Canadian institutionsVancouver General HospitalUniversity of British Columbia
Fundersnot available
KeywordsMedicineLeft atrial appendage occlusionPercutaneousAppendageCardiologyInternal medicineMeta-analysisOcclusionAtrial AppendageResidualAtrial fibrillationAnatomyWarfarinSinus rhythm

Abstract

fetched live from OpenAlex

BACKGROUND AND AIMS: Residual leaks are not infrequent after left atrial appendage occlusion. However, there is still uncertainty regarding their prognostic implications. The aim of this study is to evaluate the impact of residual leaks after left atrial appendage occlusion. METHODS: A literature search was conducted until 19 February 2023. Residual leaks comprised peri-device leaks (PDLs) on transoesophageal echocardiography (TEE) or computed tomography (CT), as well as left atrial appendage patency on CT. Random-effects meta-analyses were performed to assess the clinical impact of residual leaks. RESULTS: Overall 48 eligible studies (44 non-randomized/observational and 4 randomized studies) including 61 666 patients with atrial fibrillation who underwent left atrial appendage occlusion were analysed. Peri-device leak by TEE was present in 26.1% of patients. Computed tomography-based left atrial appendage patency and PDL were present in 54.9% and 57.3% of patients, respectively. Transoesophageal echocardiography-based PDL (i.e. any reported PDL regardless of its size) was significantly associated with a higher risk of thromboembolism [pooled odds ratio (pOR) 2.04, 95% confidence interval (CI): 1.52-2.74], all-cause mortality (pOR 1.16, 95% CI: 1.08-1.24), and major bleeding (pOR 1.12, 95% CI: 1.03-1.22), compared with no reported PDL. A positive graded association between PDL size and risk of thromboembolism was noted across TEE cut-offs. For any PDL of >0, >1, >3, and >5 mm, the pORs for thromboembolism were 1.82 (95% CI: 1.35-2.47), 2.13 (95% CI: 1.04-4.35), 4.14 (95% CI: 2.07-8.27), and 4.44 (95% CI: 2.09-9.43), respectively, compared with either no PDL or PDL smaller than each cut-off. Neither left atrial appendage patency, nor PDL by CT was associated with thromboembolism (pOR 1.45 and 1.04, 95% CI: 0.84-2.50 and 0.52-2.07, respectively). CONCLUSIONS: Peri-device leak detected by TEE was associated with adverse events, primarily thromboembolism. Residual leaks detected by CT were more frequent but lacked prognostic significance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.010
metaresearch head score (Gemma)0.021
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.011
Threshold uncertainty score0.055

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0100.021
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0110.043
Bibliometrics0.0040.005
Science and technology studies0.0010.001
Scholarly communication0.0030.001
Open science0.0020.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.170
GPT teacher head0.387
Teacher spread0.217 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations85
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueEuropean Heart JournalSame topicAtrial Fibrillation Management and OutcomesFrench-language works237,207