MétaCan
Menu
Back to cohort
Record W4389999783 · doi:10.1002/mrc.5421

A reliable external calibration method for reaction monitoring with benchtop NMR

2023· article· en· W4389999783 on OpenAlexafffund
Tristan Maschmeyer, Breanna Conklin, Thomas C. Malig, David J. Russell, Kenji L. Kurita, Jason E. Hein, José G. Napolitano

Bibliographic record

VenueMagnetic Resonance in Chemistry · 2023
Typearticle
Languageen
FieldChemistry
TopicAnalytical Chemistry and Chromatography
Canadian institutionsStructural Genomics ConsortiumUniversity of TorontoUniversity of British Columbia
FundersNatural Sciences and Engineering Research Council of CanadaGenentechUniversity of British ColumbiaCanada Foundation for Innovation
KeywordsChemistryAnalyteNuclear magnetic resonance spectroscopyCalibrationProton NMRAnalytical Chemistry (journal)RelaxometrySpectrometerBiological systemProcess engineeringNuclear magnetic resonanceChromatographyMagnetic resonance imagingSpin echoOrganic chemistry

Abstract

fetched live from OpenAlex

Nuclear magnetic resonance (NMR) spectroscopy is a powerful analytical technique with the ability to acquire both quantitative and structurally insightful data for multiple components in a test sample. This makes NMR spectroscopy a desirable tool to understand, monitor, and optimize chemical transformations. While quantitative NMR (qNMR) approaches relying on internal standards are well-established, using an absolute external calibration scheme is beneficial for reaction monitoring as resonance overlap complications from an added reference material to the sample can be avoided. Particularly, this type of qNMR technique is of interest with benchtop NMR spectrometers as the likelihood of resonance overlap is only enhanced with the lower magnetic field strengths of the used permanent magnets. The included study describes a simple yet robust methodology to determine concentration conversion factors for NMR systems using single- and multi-analyte linear regression models. This approach is leveraged to investigate a pharmaceutically relevant amide coupling batch reaction. An on-line stopped-flow (i.e., interrupted-flow or paused-flow) benchtop NMR system was used to monitor both the 1,1'-carbonyldiimidazole (CDI) promoted acid activation and the amide coupling. The results highlight how quantitative measurements in benchtop NMR systems can provide valuable information and enable analysts to make decisions in real time.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.010
metaresearch head score (Gemma)0.014
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.010
Threshold uncertainty score0.055

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0100.014
Meta-epidemiology (narrow)0.0030.001
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0030.002
Science and technology studies0.0020.002
Scholarly communication0.0020.002
Open science0.0040.002
Research integrity0.0040.005
Insufficient payload (model declined to judge)0.0070.010

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.271
Teacher spread0.257 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueMagnetic Resonance in ChemistrySame topicAnalytical Chemistry and ChromatographyFrench-language works237,207