MétaCan
Menu
Back to cohort
Record W4390605970 · doi:10.1088/1361-6501/ad1b9e

Comparison of aerosol spectrometers : accounting for evaporation and sampling losses

2024· article· en· W4390605970 on OpenAlexafffund
Xavier Lefebvre, Antonella Succar, Émilie Bédard, Michèle Prévost, Étienne Robert

Bibliographic record

VenueMeasurement Science and Technology · 2024
Typearticle
Languageen
FieldMedicine
TopicInfection Control and Ventilation
Canadian institutionsPolytechnique Montréal
FundersFonds de recherche du Québec – Nature et technologiesNatural Sciences and Engineering Research Council of CanadaHydro-QuébecPolytechnique Montréal
KeywordsAerosolEnvironmental scienceParticle-size distributionEvaporationParticle counterSampling (signal processing)BioaerosolParticle sizeMeteorologyRemote sensingMaterials scienceOpticsChemistryPhysicsDetector

Abstract

fetched live from OpenAlex

Abstract Measuring aerosol size distribution with precision is critical to understand the transmission of pathogens causing respiratory illnesses and to identify risk mitigation strategies. It is however a challenging task as the size of pathogen-carrying particles evolves over time due to evaporation. Although measurement techniques well established in the field of aerosol science are often used to characterize bioaerosols, their performance is seldom assessed with respect to evaporation and deposition in sampling lines. Four instruments providing aerosol size distribution were compared using oil and water-based particles. They each rely on different measurement principles: phase doppler anemometry, light scattering, electrical mobility and aerodynamic impaction. Size distributions of oil-based particles showed consistency across different measurement instruments, but significant discrepancies arose for water-based particles undergoing evaporation. These larger differences result from both evaporation and particle deposition in transit between the sampling point and the measurement inside the instrument. Phase doppler anemometry was best suited for precise size distribution measurement, as it eliminates the need for a sampling line, thereby preventing particle loss or evaporation during transit. With this instrument as a reference, empirical correction factors for evaporation and deposition were derived from dimensionless numbers and experimental data, enabling quantitative assessment of bioaerosol size distribution using different instruments. To obtain the size distribution at the source of the aerosol generation, complete drying of a salt solution was performed. Using the complete drying technique and accounting for losses, sampling instruments can reliably provide this critical information and allow for thorough risk assessment in the context of airborne transmission.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.064
Threshold uncertainty score0.145

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.089
GPT teacher head0.363
Teacher spread0.275 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueMeasurement Science and TechnologySame topicInfection Control and VentilationFrench-language works237,207