MétaCan
Menu
Back to cohort
Record W4390764034 · doi:10.1016/j.artd.2023.101288

The Hip-spine Assessment of a Novel Surgical Planning Software Provides Acetabular Component Targets That Are Reliable and in Agreement With Current Clinical Recommendations

2024· article· en· W4390764034 on OpenAlexaff
Emily I. McIntosh, Nana O. Sarpong, John R. Steele, Elizabeth Davis, Jeffrey M. Muir, Haley G. Canoles, Jonathan M. Vigdorchik

Bibliographic record

VenueArthroplasty Today · 2024
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsIntellijoint Surgical (Canada)
Fundersnot available
KeywordsMedicineComponent (thermodynamics)SPINE (molecular biology)Total hip replacementAcetabulumCurrent (fluid)SoftwareMedical physicsSurgeryBioinformaticsEngineeringComputer science

Abstract

fetched live from OpenAlex

Background: Spinopelvic immobility has been reported to increase dislocation risk following total hip arthroplasty. Surgically placing acetabular components in a functional orientation has been shown to mitigate risk. The aim of this study was to evaluate the validity and reliability of novel surgical planning software to generate clinically recommended cup targets. Methods: Hip-spine assessments were performed retrospectively on 40 patients. Five reviewers, including 3 arthroplasty-trained surgical fellows and 2 clinical research scientists performed the assessments. Hip-spine assessments consisted of measuring anterior pelvic plane tilt, sacral slope, pelvic incidence, and lumbar lordosis on standing anteroposterior pelvis and lateral standing and seated hip-spine images. Generated cup targets and a control group (40°/20° relative to the anterior pelvic plane) were compared to clinically recommended cup targets. Agreement was defined as a cup position within the recommended range or within 3° of a specific target (eg, 40° inclination) when no range was provided. Intraclass correlation coefficients were used to assess interrater and intrarater reliability, and McNemar's chi-square test was used to measure success relative to the control group. Results: The intraclass correlation coefficient was 0.88 for delta sacral slope and 0.92 for pelvic incidence-lumbar lordosis mismatch. For patients with spinopelvic risk factors, the generated targets matched the clinical recommendations in 81% of patients compared to only 16% in the control group. Conclusions: Excellent interrater and intrarater reliability was achieved using the novel surgical planning software. The resultant target values agreed with clinical recommendations to a greater extent than the control group.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.612
Threshold uncertainty score0.581

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.050
GPT teacher head0.359
Teacher spread0.309 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueArthroplasty TodaySame topicOrthopaedic implants and arthroplastyFrench-language works237,207