MétaCan
Menu
Back to cohort
Record W4391152033 · doi:10.1016/j.gie.2024.01.021

Impact of study design on adenoma detection in the evaluation of artificial intelligence–aided colonoscopy: a systematic review and meta-analysis

2024· review· en· W4391152033 on OpenAlexaff
Michelle Chae Min Lee, Colleen H. Parker, L W Liu, Armin Farahvash, Thurarshen Jeyalingam

Bibliographic record

VenueGastrointestinal Endoscopy · 2024
Typereview
Languageen
FieldMedicine
TopicColorectal Cancer Screening and Detection
Canadian institutionsUniversity of TorontoUniversity Health Network
Fundersnot available
KeywordsMedicineColonoscopyMeta-analysisAdenomaGeneral surgerySystematic reviewMedical physicsMEDLINEInternal medicineColorectal cancer

Abstract

fetched live from OpenAlex

BACKGROUND AND AIMS: Randomized controlled trials (RCTs) have reported that artificial intelligence (AI) improves endoscopic polyp detection. Different methodologies-namely, parallel and tandem designs-have been used to evaluate the efficacy of AI-assisted colonoscopy in RCTs. Systematic reviews and meta-analyses have reported a pooled effect that includes both study designs. However, it is unclear whether there are inconsistencies in the reported results of these 2 designs. Here, we aimed to determine whether study characteristics moderate between-trial differences in outcomes when evaluating the effectiveness of AI-assisted polyp detection. METHODS: A systematic search of Ovid MEDLINE, Embase, Cochrane Central, Web of Science, and IEEE Xplore was performed through March 1, 2023, for RCTs comparing AI-assisted colonoscopy with routine high-definition colonoscopy in polyp detection. The primary outcome of interest was the impact of study type on the adenoma detection rate (ADR). Secondary outcomes included the impact of the study type on adenomas per colonoscopy and withdrawal time, as well as the impact of geographic location, AI system, and endoscopist experience on ADR. Pooled event analysis was performed using a random-effects model. RESULTS: = 62%; P < .001), with no statistical subgroup difference between study design. Both tandem and parallel study designs revealed improvement in adenomas per colonoscopy in AI-aided colonoscopies, but this improvement was more marked among tandem studies (P < .001). AI assistance significantly increased withdrawal times for parallel (P = .002), but not tandem, studies. ADR improvement was more marked among studies conducted in Asia compared to Europe and North America in a subgroup analysis (P = .007). Type of AI system used or endoscopist experience did not affect overall improvement in ADR. CONCLUSIONS: Either parallel or tandem study design can capture the improvement in ADR resulting from the use of AI-assisted polyp detection systems. Tandem studies powered to detect differences in endoscopic performance through paired comparison may be a resource-efficient method of evaluating new AI-assisted technologies.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.021
metaresearch head score (Gemma)0.055
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch, Meta-epidemiology (broad)
Consensus categoriesnone
DomainCandidate signal: Methods · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.982
Threshold uncertainty score0.112

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0210.055
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0180.038
Bibliometrics0.0030.004
Science and technology studies0.0010.001
Scholarly communication0.0040.002
Open science0.0020.002
Research integrity0.0040.003
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.273
GPT teacher head0.460
Teacher spread0.187 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

Study designMeta-analysis
DomainMethods
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations32
Published2024
Admission routes1
Has abstractno

Explore more

Same venueGastrointestinal EndoscopySame topicColorectal Cancer Screening and DetectionFrench-language works237,207