MétaCan
Menu
Back to cohort
Record W4391227901 · doi:10.1186/s13065-024-01116-3

Development of a green synchronous spectrofluorimetric technique for simultaneous determination of Montelukast sodium and Bilastine in pharmaceutical formulations

2024· article· en· W4391227901 on OpenAlexaff
Sayed M. Derayea, Khalid M. Badr El‐Din, Ahmed S. Ahmed, Ahmed A. Khorshed, Mohamed Oraby

Bibliographic record

VenueBMC Chemistry · 2024
Typearticle
Languageen
FieldChemistry
TopicAnalytical Methods in Pharmaceuticals
Canadian institutionsUniversity of Alberta
FundersScience and Technology Development Fund
KeywordsMontelukastChromatographyChemistryDerivative (finance)SodiumAsthmaMedicineInternal medicineOrganic chemistry

Abstract

fetched live from OpenAlex

Abstract For the treatment of rhinitis and asthma, a combination of Montelukast sodium and Bilastine has just been approved. Based on the first derivative of synchronous fluorescence, the current work developed a green, highly accurate, sensitive, and selective spectroscopic approach for estimating Montelukast sodium and Bilastine in pharmaceutical dosage form without previous separation. The selected technique focuses on measuring the synchronized fluorescence of the studied medications at a fixed wavelength range (Δλ) = 110 nm, and using the amplitude of the first derivative's peak at 381 and 324 nm, for quantitative estimation of Montelukast sodium and Bilastine, respectively. The impacts of different factors on the referred drugs' synchronized fluorescence intensity were investigated and adjusted. The calibration plots for were found to be linear over concentration ranges of 50–2000 ng mL −1 for Montelukast sodium and 50–1000 ng mL −1 for Bilastine. Montelukast sodium and Bilastine have LODs of 16.5 and 10.9 ng mL −1 , respectively. In addition, LOQs were: 49.9 and 33.0 ng mL −1 , for both drugs, respectively. The developed method was successfully employed to quantify the two drugs in synthetic tablets mixture and in laboratory prepared mixtures containing varied Montelukast and Bilastine ratios. To compare the results with the published analytical approach, a variance ratio F-test and a student t-test were used, which revealed no significant differences.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.050
GPT teacher head0.379
Teacher spread0.329 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations28
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueBMC ChemistrySame topicAnalytical Methods in PharmaceuticalsFrench-language works237,207