MétaCan
Menu
Back to cohort
Record W4391430875 · doi:10.1093/jalm/jfad133

Whole Blood Cardiac Troponin “Triaging” to Improve Early Detection of Myocardial Injury at a Pediatric Hospital

2024· article· en· W4391430875 on OpenAlexafffund
Lawrence de Koning, Isolde Seiden‐Long, Katherine Anker, Kimberley Myers, Antonia Stang

Bibliographic record

VenueThe Journal of Applied Laboratory Medicine · 2024
Typearticle
Languageen
FieldMedicine
TopicAcute Myocardial Infarction Research
Canadian institutionsAlberta Children's HospitalCalgary Laboratory ServicesUniversity of Calgary
FundersAlberta Precision Laboratories
KeywordsTroponin complexMedicineTroponin ITriageCardiologyEmergency medicineInternal medicineMyocardial infarction

Abstract

fetched live from OpenAlex

BACKGROUND: The importance of offering on-site cardiac troponin (cTn) testing at pediatric hospitals may be underappreciated. We developed a rapid rule-in process for myocardial injury at a pediatric hospital experiencing delays in off-site high-sensitivity cardiac troponin T (hs-cTnT) testing. METHODS: Collect-to-verify turnaround times (TATs) for off-site testing were reviewed. Pre-analytic changes to improve TATs were devised, implemented and evaluated, after which a new analyzer was selected and evaluated for on-site cTn testing. Performance of the new analyzer's assay was compared to the off-site hs-cTnT assay, and post go-live TATs for on-site testing were assessed. RESULTS: Median collect-to-verify TAT for short turnaround-time (STAT) priority off-site plasma hs-cTnT testing was 104 min, with 35% of orders having a TAT >120 min. Eliminating serum separator tubes and requiring a separate plasma separator tube did not significantly reduce TATs. A QuidelOrtho Triage® MeterPro whole blood cardiac troponin I (cTnI) assay was implemented to "triage" time-critical and STAT priority specimens collected for off-site hs-cTnT testing. Elevated cTnI (≥0.02 µg/L) had a sensitivity of 91% for clear elevations in hs-cTnT (≥53 ng/L) but a 0% sensitivity for modest elevations (5 to 13 ng/L, 14 to 52 ng/L). An interpretive comment was auto-appended to cTnI results indicating that clinicians should wait for the hs-cTnT result if cTnI was normal. Median collect-to-verify TAT for on-site cTnI testing was <50% the TAT for off-site hs-cTnT testing. CONCLUSIONS: On-site point-of-care whole blood cTn testing can rapidly confirm significant or late-presenting myocardial injury. Combined with simultaneous off-site high-sensitivity cardiac troponin (hs-cTn) testing, this workflow is a viable interim solution for pediatric hospitals without on-site hs-cTn testing.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.011
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.011
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.267
Teacher spread0.261 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueThe Journal of Applied Laboratory MedicineSame topicAcute Myocardial Infarction ResearchFrench-language works237,207