MétaCan
Menu
Back to cohort
Record W4391540773 · doi:10.1016/j.jhlto.2024.100064

Impact of HeartWare ventricular assist device discontinuation on the pediatric population: An Advanced Cardiac Therapies Improving Outcomes Network (ACTION) registry analysis

2024· article· en· W4391540773 on OpenAlexaff
Robert A. Niebler, Muhammad Shezad, Mohammed Absi, Othman A. Aljohani, Shahnawaz Amdani, Scott R. Auerbach, David W. Bearl, K Boucek, Holger Buchholz, Chesney Castleberry, John C. Dykes, K. Engelhardt, Joshua Friedland‐Little, Kyle D. Hope, Mehreen Iqbal, Aamir Jeewa, Anna Joong, Angela Lorts, Lindsay J. May, Deepa Mokshagundam, Deipanjan Nandi, Matthew J. O’Connor, John J. Parent, David M. Peng, Natalie Shwaish, Svetlana Shugh, Christina VanderPluym, Gabrielle Vaughn, Mattew Zinn

Bibliographic record

VenueJHLT Open · 2024
Typearticle
Languageen
FieldEngineering
TopicMechanical Circulatory Support Devices
Canadian institutionsHospital for Sick ChildrenUniversity of Alberta
FundersAbiomed
KeywordsMedicineVentricular assist deviceDiscontinuationStroke (engine)PopulationAdverse effectInternal medicineEmergency medicineCardiologyHeart failure

Abstract

fetched live from OpenAlex

Background: The HeartWare ventricular assist device (HVAD) was discontinued in July 2021. The study aims to describe the impact the discontinuation the HVAD had on pediatric ventricular assist device (VAD) utilization and outcomes. Methods: . Results were compared from before and after July 2021. All patients in the registry implanted with an HVAD were reported to determine overall outcomes of these patients and define who remains on the device. Results: The HeartMate 3 (HM3) primarily replaced the HVAD in pediatric patients increasing from 29 of 258 (11%) of implants before July 2021 to 31 of 109 (29%) of implants after. A small increase in the use of the Berlin Heart EXCOR (40 of 258, 16% before to 20 of 109, 18% after) and paracorporeal continuous flow devices (116 of 258, 45% before to 58 of 109, 53% after) was also observed. The rate of ischemic stroke increased in the overall population and a decrease in bleeding complications in the EXCOR group was observed. Of the 187 pediatric patients implanted with an HVAD in the registry, 7 patients remain supported, 1 patient transitioned from the HVAD to an HM3, and 6 patients were lost to follow-up. Conclusions: The HM3 has been the primary replacement for the HVAD in the medium-sized pediatric population. The rate of ischemic stroke was higher after July 2021.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.086
Threshold uncertainty score0.491

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.319
Teacher spread0.291 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueJHLT OpenSame topicMechanical Circulatory Support DevicesFrench-language works237,207