Abstract

fetched live from OpenAlex

The abundance of straw in Quebec makes this material an interesting insulation option to reduce the energy consumption of buildings. At the same time, studies indicate that straw bales’ outstanding hygrothermal performance can provide a comfortable living experience for the occupants. However, due to the slightly higher thermal conductivity of straw bales insulation compared to common insulation materials, the walls are found to be 30–90% thicker, which can lead to moisture-related problems especially under a humid and cold outdoor climate. Therefore, a split-insulation wall structure was used in this study to reduce the wall thickness by combining straw bales with expanded polystyrene (EPS) exterior insulation. Results show that straw bale walls generally have higher thermal inertia and better moisture buffer capacity compared to the reference wall using glass fiber insulation. The hygrothermal profiles show that the sheathing-insulation interface is the position having the highest relative humidity in the walls. The biohygrothermal model also suggests that under Quebec’s climate, the mould grow risk in a straw bales wall with two inches EPS exterior insulation is within acceptable limits.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.023
Threshold uncertainty score0.045

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.193
Teacher spread0.186 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2024
Admission routes3
Has abstractyes

Explore more

Same venueEnergy and BuildingsSame topicHygrothermal properties of building materialsFrench-language works237,207