MétaCan
Menu
← Back to cohort
Record W4392160702 · doi:10.1111/cid.13316

Effect of prefabricated immediate interim prosthesis design and insertion workflow on seating accuracy on implants placed via static computer‐assisted implant surgery: A cross‐sectional in vitro study

2024· article· en· W4392160702 on OpenAlexvenueno aff
Jaafar Abduo, Douglas Lau

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2024
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
FundersInternational Team for ImplantologyUniversity of Melbourne
KeywordsProsthesisInterimImplantDental prosthesisOrthodonticsWorkflowDentistryBiomedical engineeringMedicineComputer scienceSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: Immediate implant restoration by prefabricated prosthesis has multiple benefits. However, the design and insertion workflow of the prosthesis may influence the seating. PURPOSE: Evaluation of seating accuracy of prefabricated interim prosthesis of different designs and insertion workflows for immediate restoration of implants placed via static computer-assisted implant surgery (sCAIS). MATERIALS AND METHODS: A maxillary model without incisors was used to plan for two implants at the lateral incisor locations. According to the planned implants, sCAIS surgical template and a four-unit interim prosthesis were designed. Four prostheses were fabricated based on the design and insertion workflow. The first prosthesis involved complete fabrication (CF) of the interim prosthesis, where the interim prosthesis is fabricated for laboratory attachment to abutments. The other three prostheses were produced by partial fabrication (PF), where the interim prosthesis shell was produced with internal spacing between the fitting surface and the abutments. The PF prostheses were cemented on abutments attached to the inserted implants. Three different PF prosthesis designs were included with different levels of internal spacing: 100 μm (PF.1), 200 μm (PF.2), and 300 μm (PF.3). A total of 15 surgical models received implants on which each prosthesis was seated and scanned by a laboratory scanner. The vertical, horizontal, and proximal contact errors were measured. RESULTS: Although all prostheses were seated on every model, the CF prostheses had greater vertical error, followed by PF.1, PF.2, and PF.3 prostheses, respectively. A similar pattern was observed for proximal contact error, where PF.3 was most superior. PF.3 prostheses had the least horizontal error than the other prostheses. CONCLUSIONS: All interim prostheses experienced errors at the vertical, horizontal, and proximal surfaces, which can be attributed to deviations of the inserted implants. The PF of interim prosthesis with increased internal spacing for intraoral insertion appeared to reduce seating errors.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.141
GPT teacher head0.477
Teacher spread0.336 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→