MétaCan
Menu
Back to cohort
Record W4392392260 · doi:10.1002/clc.24249

Letter regarding “Anteriolateral versus anterior–posterior electrodes in external cardioversion of atrial fibrillation: A systematic review and meta‐analysis of clinical trials”

2024· review· en· W4392392260 on OpenAlexaff
Stephanie T. Nguyen, Emilie P. Belley‐Côté, William F. McIntyre

Bibliographic record

VenueClinical Cardiology · 2024
Typereview
Languageen
FieldMedicine
TopicAtrial Fibrillation Management and Outcomes
Canadian institutionsPopulation Health Research InstituteMcMaster University
Fundersnot available
KeywordsMedicineAtrial fibrillationCardioversionCardiologyClinical trialMeta-analysisInternal medicine

Abstract

fetched live from OpenAlex

The optimal electrode pad placement for successful cardioversion of atrial fibrillation (AF) remains unknown. In a systematic review and meta-analysis of 11 trials, Motawea et al. concluded that anterolateral (AL) positioned pads are more effective than anterior-posterior (AP) positioned pads for electrical cardioversion of patients with AF (odds ratio: 1.40, 95% confidence interval [CI]: 1.02–1.92, p = .04).1 We previously reported a systematic review and meta-analysis of randomized controlled trials of techniques to improve cardioversion success. In contrast to Motawea et al., we found that overall cardioversion success did not differ when comparing AL to AP-positioned pads (Risk ratio: 1.01, 95% CI: 0.96–1.06, p = .70).2 Two principal issues drive the differences between our studies' results. The first issue relates to study selection. Motawea et al. omitted four randomized trials that were included in our meta-analysis, this represents 389 extra participants or 21% more participants.3-6 They also erroneously included one prospective observational cohort study (111 participants).7 The second issue relates to data appraisal and/or data abstraction. The authors have recorded incorrect values for the trials by Alp et al. and Botto et al.8, 9 For these two trials, the authors appear not to have followed the intention to treat principle; some abstracted values represent cross-overs rather than the pad placements to which the patients were initially randomized. We, therefore, advise caution when interpreting the study by Motawea et al.; AL pad placement has not been shown to be superior to AP placement. A definitive trial addressing the question is ongoing (NCT05511389).10 An additional important limitation of these data not raised by Motawea et al., is that pad placement has rarely been tested in studies where participants were consistently receiving other co-interventions that have been proven effective (i.e., high energy and biphasic shocks). A large randomized controlled trial comparing pad placement in patients with AF with other best practices in place is thus warranted. The authors declare no conflict of interest.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.020
metaresearch head score (Gemma)0.105
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Commentary · Consensus signal: Commentary
Teacher disagreement score0.021
Threshold uncertainty score0.104

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0200.105
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0040.004
Bibliometrics0.0020.003
Science and technology studies0.0020.002
Scholarly communication0.0040.003
Open science0.0030.002
Research integrity0.0210.013
Insufficient payload (model declined to judge)0.0110.007

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.421
GPT teacher head0.550
Teacher spread0.129 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreCommentary

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueClinical CardiologySame topicAtrial Fibrillation Management and OutcomesFrench-language works237,207