MétaCan
Menu
Back to cohort
Record W4392782502 · doi:10.1055/a-2271-2145

Outcomes predictors in endoscopic ultrasound-guided choledochoduodenostomy with lumen-apposing metal stent: Systematic review and meta-analysis

2024· article· en· W4392782502 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueEndoscopy International Open · 2024
Typearticle
Languageen
FieldMedicine
TopicGallbladder and Bile Duct Disorders
Canadian institutionsSt. Michael's Hospital
Fundersnot available
KeywordsMedicineEndoscopic ultrasoundLumen (anatomy)Meta-analysisRadiologyStentSurgeryPathology

Abstract

fetched live from OpenAlex

Abstract Background and study aims EUS-guided choledochoduodenostomy (EUS-CDS) is a minimally invasive procedure used to treat malignant biliary obstruction (MBO) by transduodenal placement of a lumen-apposing metal stent (LAMS) into the extrahepatic bile duct. To identify factors that contribute to safe and effective EUS-CDS using LAMS, we performed a systematic review of the literature and meta-analysis. Methods The methodology of our analysis was based on PRISMA recommendations. Electronic databases (Medline, Scopus, EMBASE) were searched up to November 2022. Full articles that included patients with distal malignant biliary obstruction who underwent EUS-CDS using LAMS after failed endoscopic retrograde cholangiopancreatography were eligible. Random-effect meta-analysis was performed reporting pooled rates of technical success, clinical success, and adverse events (AEs) by means of a random model. Multivariate meta-regression and subgroup analysis were performed to assess possible associations between the outcomes and selected variables to assess the correlation between outcomes and different variables. Results were also stratified according to stent size. Results Twelve studies with 845 patients were included in the meta-analysis. Pooled technical and clinical success rates were 96% (95% confidence interval [CI] 94%-98%; I2 = 52.29%) and 96% (95%CI 95%-98%), respectively, with no significant association with baseline characteristics, such are sex, age, common bile duct diameter, or stent size. The pooled AE rate was 12% (95%CI: 8%-16%; I2 = 71.62%). The AE rate was significantly lower when using an 8 × 8 mm stent as compared with a 6 × 8 mm LAMS (odds ratio 0.59, 0.35–0.99; P = 0.04), with no evidence of heterogeneity (I2 = 0%). Conclusions EUS-CDS with LAMS is a safe and effective option for relief of MBO. Selecting an appropriate stent size is crucial for achieving optimal safety outcomes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.584
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0020.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.037
GPT teacher head0.352
Teacher spread0.314 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it