Long-Term Outcomes of High-Flexion Design Total Knee Arthroplasty with a Short Posterior Flange
Bibliographic record
Abstract
Background: The purpose of this study was to evaluate the clinical and radiological outcomes of high-flexion total knee arthroplasty (TKA) using Vega Knee System (B. Braun, Aesculap) at a long-term follow-up and to analyze the implant survivorship. Methods: We enrolled 165 patients (232 knees) with a minimum 7-year follow-up after TKA (VEGA Knee System). For clinical assessment, range of motion (ROM), Knee Injury and Osteoarthritis Outcome Score (KOOS), and Western Ontario and McMaster University Osteoarthritis Index (WOMAC) were used. For radiologic assessment, hip-knee-ankle angle, component position, and the existence of radiolucent lines and loosening were used. Survival analysis was conducted using the Kaplan-Meier method. Results: < 0.001). Revision TKA was performed in 10 cases (4.3%), which included 9 cases of aseptic loosing and 1 case of periprostatic joint infection. Of the 9 aseptic loosening cases (3.9%), 8 cases (3.4%) were loosening of the femoral component and 1 case (0.4%) was loosening of the tibial component. When revision for any reason was considered an endpoint, the 10-year survivorship was 96.2% (95% confidence interval [CI], 93.9%-98.5%). On the other hand, when revision for aseptic loosening was considered the endpoint, the 10-year survivorship was 96.6% (95% CI, 94.4%-98.8%). Conclusions: The Vega Knee System provided good clinical results in the long-term follow-up period. Although the VEGA Knee System showed acceptable implant survivorship, loosening of the femoral component occurred in about 3.4% of the patients. For more accurate evaluation of the survivorship of high-flexion design TKA with a short posterior flange, it is necessary to conduct more long-term follow-up studies targeting diverse races, especially Asians who frequently perform high-flexion activities.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.002 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".