MétaCan
Menu
Back to cohort
Record W4393005303 · doi:10.1136/ejhpharm-2024-eahp.97

3PC-040 Radiochemical purity determination of 177Lu-PSMA-617: development and validation of a high-performance liquid chromatography analytical method

2024· article· en· W4393005303 on OpenAlexfundno aff
A. J. Salle, Juliette Fouillet, Charlotte Donzé, Léa Rubira, Cyril Fersing

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldMedicine
TopicRadiopharmaceutical Chemistry and Applications
Canadian institutionsnot available
FundersInstitute of Cancer ResearchAgence Nationale de Sécurité du Médicament et des Produits de SantéUniversité Claude Bernard Lyon 1Hospices Civils de LyonCentre National de la Recherche Scientifique
KeywordsHigh-performance liquid chromatographyChemistryChromatographyCoefficient of variationDetection limitLinearityAnalytical Chemistry (journal)Nuclear medicineMedicinePhysics

Abstract

fetched live from OpenAlex

Background and Importance 177Lu-PSMA-617 is a treatment of progressive, metastatic, castration-resistant prostate cancers expressing PSMA receptors, previously treated with taxane and at least one second-generation hormone therapy. 177Lu-PSMA-617 is a radiopharmaceutical drug with a marketing authorisation and is manufactured industrially (PLUVICTO®, Novartis). However, it can also be prepared in-house, especially for preclinical applications. Thus, quality control procedures are required to determine radiochemical purity (RCP). Aim and Objectives To develop and validate a radio-high-performance liquid chromatography (HPLC) analysis method to measure RCP of 177Lu-PSMA-617. Material and Methods Radio-HPLC analyses were carried out on an apparatus equipped with a C18 column and a radioactivity detector. Three commercial 177Lu-PSMA-617 batches were used as samples. The parameters considered for method validation were specificity, linearity, accuracy, precision, robustness, limits of detection (LOD) and limits of quantification (LOQ). Means, standard deviations and coefficient of variation (CV) for RCP, retention time (tr) and recovery were calculated. Linear regression coefficient R2 was computed for linearity. Results Radiochemical identification of 177Lu-PSMA-617 consisted in 10 analyses of each three commercial batches and showed a consistent tr of 10.07 min (CV% < 0.1). Recovery was excellent, with 12.87 ± 0.06 MBq recovered at column outlet for a 12.2 MBq injected activity. The addition of radio-impurities in known quantities validated the accuracy of the method (differences between measured RCP and theoretical RCP ranging from 101.57% to 105.52%). CV% of RCP and tr values over 12 measures of a single batch were respectively <0.11% and <0.12%, which confirmed the repeatability of the method. Forced degradation conditions in the presence of acid, base, oxidative stress or heating led to the formation in situ of impurities with a tr largely different from the analyte, confirming the specificity of the method. LOQ and LOD were 0.68 and 0.21 MBq/mL, respectively, and the radiodetector response was linear from 2 to 300 MBq/mL (R2 = 0.9977). Robustness was found to be limited as the mean tr values varied by -4.8% when the column was heated to 50 °C instead of 25 °C. Conclusion and Relevance A radio-HPLC method for the quality control of 177Lu-PSMA-617 was validated and can be used for in-house preparations for preclinical purposes of this radioactive drug. References and/or Acknowledgements Conflict of Interest No conflict of interest.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.004
Threshold uncertainty score0.021

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.005
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0020.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.345
Teacher spread0.319 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2024
Admission routes1
Has abstractyes

Explore more

Same topicRadiopharmaceutical Chemistry and ApplicationsFrench-language works237,207