MétaCan
Menu
Back to cohort
Record W4393042525 · doi:10.3390/electronics13061154

A Low-Intensity Pulsed Ultrasound Interface ASIC for Wearable Medical Therapeutic Device Applications

2024· article· en· W4393042525 on OpenAlexaff
Xuanjie Ye, Xiaoxue Jiang, Shuren Wang, Jie Chen

Bibliographic record

VenueElectronics · 2024
Typearticle
Languageen
FieldEngineering
TopicUltrasound and Hyperthermia Applications
Canadian institutionsUniversity of Alberta
FundersChina Scholarship Council
KeywordsApplication-specific integrated circuitLow-intensity pulsed ultrasoundVoltageElectrical engineeringComputer scienceElectronic engineeringEmbedded systemEngineeringTherapeutic ultrasoundUltrasoundPhysics

Abstract

fetched live from OpenAlex

Low-intensity pulsed ultrasound (LIPUS) is a non-invasive medical therapy that has attracted recent research interest due to its therapeutic effects. However, most LIPUS driver systems currently available are large and expensive. We have proposed a LIPUS interface application-specific integrated circuit (ASIC) for use in wearable medical devices to address some of the challenges related to the size and cost of the current technologies. The proposed ASIC is a highly integrated system, incorporating a DCDC module based on a charge pump architecture, a high voltage level shifter, a half-bridge driver, a voltage-controlled oscillator, and a corresponding digital circuit module. Consequently, the functional realization of this ASIC as a LIPUS driver system requires only a few passive components. Experimental tests indicated that the chip is capable of an output of 184.2 mW or 107.2 mW with a power supply of 5 V or 3.7 V, respectively, and its power conversion efficiency is approximately 30%. This power output capacity allows the LIPUS driver system to deliver a spatial average temporal average (SATA) of 29.5 mW/cm2 or 51.6 mW/cm2 with a power supply of 3.7 V or 5 V, respectively. The total die area, including pads, is 4 mm2. The ASIC does not require inductors, improving its magnetic resonance imaging (MRI) compatibility. In summary, the proposed LIPUS interface chip presents a promising solution for the development of MRI-compatible and cost-effective wearable medical therapy devices.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.253
Teacher spread0.244 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueElectronicsSame topicUltrasound and Hyperthermia ApplicationsFrench-language works237,207