MétaCan
Menu
Back to cohort
Record W4393077220 · doi:10.52225/narra.v4i1.637

Nearly catastrophe coronary perforation: Is it second drug-eluting stent effective?

2024· article· en· W4393077220 on OpenAlexaboutno aff
Haris Munirwan, Tjut Farahiya Hadi, Adi Purnawarman, Muhammad H. Latief, Wittawat Wattanasiriporn, Teuku Yusrizal

Bibliographic record

VenueNarra J · 2024
Typearticle
Languageen
FieldMedicine
TopicCoronary Interventions and Diagnostics
Canadian institutionsnot available
Fundersnot available
KeywordsPerforationDrug-eluting stentDrugMedicineStentCardiologyInternal medicineEngineeringPharmacologyMechanical engineering

Abstract

fetched live from OpenAlex

Coronary artery perforation (CAP) is an uncommon yet serious complication. Although severe perforations (Ellis III) have become more frequent, the overall mortality rate associated with perforations (7.5%) has decreased in recent years. Unfortunately, our medical facility cannot always access a cover stent. The aim of this case report was to demonstrate the effectiveness of using a second drug-eluting stent as an alternative and successful treatment approach in a CAP patient. This is the case of a 67-year-old female with stable angina pectoris Canadian Cardiovascular Society classification III (CCS III), three-vessel coronary artery disease (CAD), who declined CABG (Syntax score of 44) and had type II diabetes mellitus. The patient underwent elective percutaneous coronary intervention (PCI), and we identified diffuse stenosis in the proximal to distal portions of the left anterior descending artery (LAD) with extensive calcification. Furthermore, there was a chronic total occlusion (CTO) in obtuse marginal (OM) 2, as well as critical stenosis in OM3, 80% stenosis in the proximal part of right coronary artery (RCA), 90% stenosis in the middle of the RCA, 90-95% in the distal RCA, and diffuse stenosis ranging from 70-80% in the distal posterolateral. During the procedure to alleviate the stenosis in the left circumflex artery (LCx), we encountered a coronary perforation classified as Ellis type III while using a 2.5/20 mm NC balloon inflated to 12 atm for 12 seconds. In response, we performed stent placement from the proximal LCx to OM2 using the Xience Xpedition drug-eluting stent (DES) measuring 2.5/28 mm. Subsequently, we conducted extended balloon inflation (intermittent) for five minutes. Despite these efforts, the coronary perforation, still classified as Ellis type III, persisted. We decided to employ intrastent stenting (a second DES strategy) with the Coroflex Isar DES measuring 2.5/28 mm, followed by prolonged balloon inflation. The outcome revealed no remaining perforation, Thrombolysis in Myocardial Infarction (TIMI) III flow, and no complications such as pericardial effusion after 48 hours of monitoring. The implantation of a second DES proved to be a practical approach for managing a significant CAP.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesInsufficient payload (model declined to judge)
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.251
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0090.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.294
Teacher spread0.277 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; both teacher heads agree on what is shown here.

Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueNarra JSame topicCoronary Interventions and DiagnosticsFrench-language works237,207