Non-surgical interventions to control bleeding from arteriovenous fistulas and grafts inside and outside the hemodialysis unit: a scoping review

2024· review· en· W4393276617 on OpenAlexaff
Elizabeth Milosevic, Adam Forster, Louise Moist, Faisal Rehman, A. B. R. Thomson

Bibliographic record

VenueClinical Kidney Journal · 2024
Typereview
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsWestern University
Fundersnot available
KeywordsHemodialysisMedicinePsychological interventionArteriovenous fistulaSurgeryVascular accessIntensive care medicineNursing

Abstract

fetched live from OpenAlex

Background: Prolonged bleeding from arteriovenous fistulas (AVF) and arteriovenous grafts (AVG) associates with worse outcomes; Within the hemodialysis unit these outcomes include anemia and quality of life disruptions, and outside the hemodialysis unit includes fatal hemorrhage. However, various guidelines for AVF/AVG bleeding management inside and outside the hemodialysis unit lack consensus. Methods: A scoping review was conducted of four databases, from inception to 17 February 2024. The study population was hemodialysis patients experiencing bleeding from AVF or AVG. Studies that assessed non-operative management were included. Results: < .05), respectively. Use of chitosan-based dressings decreased percentage of patients bleeding 4-min post-cannulation by 16.3%-39.2%. One pilot observational study demonstrated no access thromboses or infections with short-term use of a compression device within the hemodialysis unit. However, the role of compression devices and tourniquets within the dialysis unit remains unclear, despite widespread use. Long-term AVF/AVG survival was not reported in any study. Limited research confirms that devices are effective in prevention of catastrophic out-of-hospital bleeding. It remains uncertain if device availability enhances patient confidence in managing out-of-hospital bleeding. This may impact patient choices around dialysis modality, access and transplant, but this remains uncertain. Conclusions: In hemodialysis patents with bleeding from AVF/AVG, several alternative dressings or devices decrease post-cannulation bleeding time within the hemodialysis unit. Existing research has not established criteria on when it might be appropriate to use specialized dressings. There is very limited research on methods to control bleeding from AVF/AVG outside the hemodialysis unit. More data are required before evidence-based guidelines can be made. Recommendations for future research are provided.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.003
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Science and technology studies, Research integrity
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.803
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0060.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0050.003
Bibliometrics0.0000.001
Science and technology studies0.0010.000
Scholarly communication0.0000.000
Open science0.0010.001
Research integrity0.0010.005
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.200
GPT teacher head0.522
Teacher spread0.322 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designOther design
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueClinical Kidney JournalSame topicCentral Venous Catheters and HemodialysisFrench-language works237,207