MétaCan
Menu
Back to cohort
Record W4393857849 · doi:10.1016/j.tjnut.2024.03.019

Assessing Accuracy and Precision of Hemoglobin Determination in Venous, Capillary Pool, and Single-Drop Capillary Blood Specimens Using three Different HemoCue® Hb Models: The Multicountry Hemoglobin Measurement (HEME) Study

2024· article· en· W4393857849 on OpenAlexafffund
Laura S. Hackl, Crystal D Karakochuk, Dora Inés Mazariegos, Kidola Jeremiah, Omar Obeid, Nirmal Ravi, Desalegn A Ayana, Veronica Varela, Silvia Alayón, Omar Dary, Denish Moorthy

Bibliographic record

VenueJournal of Nutrition · 2024
Typearticle
Languageen
FieldMedicine
TopicIron Metabolism and Disorders
Canadian institutionsUniversity of British Columbia
FundersEduCanadaGlobal Affairs CanadaUnited States Agency for International Development
KeywordsVenous bloodHemoglobinMedicineCapillary actionHematology analyzerLimits of agreementPopulationInternal medicineNuclear medicineMaterials science

Abstract

fetched live from OpenAlex

BACKGROUND: Anemia prevalence estimates reported in population surveys can vary based on the blood specimen source (capillary or venous) and analytic device (hematology autoanalyzers or portable hemoglobinometers) used for hemoglobin (Hb) determination. OBJECTIVES: This study aimed to compare accuracy and precision of Hb measurement in three blood specimen types on three models of hemoglobinometers against the results from venous blood from the same individuals measured on automated analyzers (AAs). METHODS: This multisite (Cambodia, Ethiopia, Guatemala, Lebanon, Nigeria, and Tanzania) study assessed Hb measurements in paired venous and capillary blood specimens from apparently healthy women (aged 15-49 y) and children (aged 12-59 mo) using three HemoCue® Hb models (201+, 301, and 801). Measurements were compared against reference values: venous blood in hematology AA and adjusted via regression calibration or mean difference in HemoCue® Hb. Venous, capillary pool, and single-drop capillary blood specimens were assessed for accuracy and precision. RESULTS: Venous blood measured using HemoCue® Hb 301 exhibited a positive mean error, whereas responses in HemoCue® Hb 201+ and 801 were nondirectional compared with the reference. Adjustment with the reference harmonized mean errors for all devices across study sites to <1.0 g/L using venous blood. Precision was highest for venous blood (±5-16 g/L) in all sites, lowest for single-drop capillary (±9-37 g/L), and intermediate (±9-28 g/L) for capillary pool blood specimen. Imprecision differed across sites, especially with both capillary blood specimens, suggesting different levels of personnel skills. CONCLUSIONS: Findings suggest that venous blood is needed for accurate and precise Hb determination. Single-drop capillary blood use should be discouraged owing to high measurement variability. Further research should evaluate the viability and reliability of capillary pool blood for this purpose. Accuracy of HemoCue® Hb devices can be improved via standardization against results from venous blood assessed using AA.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.014
metaresearch head score (Gemma)0.014
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.014
Threshold uncertainty score0.071

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0140.014
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.061
GPT teacher head0.307
Teacher spread0.245 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations25
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueJournal of NutritionSame topicIron Metabolism and DisordersFrench-language works237,207