MétaCan
Menu
Back to cohort
Record W4393960770 · doi:10.1016/j.enbuild.2024.114132

The impact of real-time carbon dioxide awareness on occupant behavior and ventilation rates in student dwellings

2024· article· en· W4393960770 on OpenAlexaff
Diane Bastien, Dusan Licina, Leonidas Bourikas, Sarah Crosby, Stephanie Gauthier, Isabel Miño-Rodríguez, Cristina Piselli

Bibliographic record

VenueEnergy and Buildings · 2024
Typearticle
Languageen
FieldEngineering
TopicBuilding Energy and Comfort Optimization
Canadian institutionsUniversity of British Columbia
FundersSyddansk UniversitetÉcole Polytechnique Fédérale de LausanneNetherlands eScience Center
KeywordsVentilation (architecture)Carbon dioxideEnvironmental scienceArchitectural engineeringEngineeringMechanical engineeringChemistry

Abstract

fetched live from OpenAlex

Although existing standards typically prescribe fixed ventilation rates, a large portion of the building stock lacks mechanical ventilation systems. Such buildings obtain outdoor air through unintentional infiltration, open windows, and the operation of exhaust fans, which are mainly dependent on user awareness and behavior. This study investigates whether the presence of a simple CO2 meter display can alter user behavior and improve indoor air quality (IAQ) in dwellings. We conducted a two-week monitoring of CO2 concentration, air temperature, and relative humidity in 60 student dwellings (bedrooms and living rooms) in Denmark and Switzerland. During the first week, the CO2 display was concealed, and occupants adhered to their usual routines. In the second week, occupants used the display's visual feedback to enhance IAQ when necessary. Results revealed that over 95% of dwellings witnessed a reduction in median CO2 levels during the second week, both overall and in individual rooms. Furthermore, a descriptive analysis of CO2 concentration step changes exceeding the thresholds of “normal variation” showed an increase in the number of negative step changes, indicating a shift in user behavior. These findings underscore the efficacy ofa display interface providing information on the indoor environment in triggering behavior changes and improving IAQ in dwellings.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.131
Threshold uncertainty score0.341

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.260
Teacher spread0.253 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueEnergy and BuildingsSame topicBuilding Energy and Comfort OptimizationFrench-language works237,207