MétaCan
Menu
Back to cohort
Record W4394065319 · doi:10.1016/j.talanta.2024.126032

Evaluation of thin film microextraction based on graphene oxide/ polymer composite: Experimental and theoretical insights

2024· article· en· W4394065319 on OpenAlexafffund
Khaled Murtada, Janusz Pawliszyn

Bibliographic record

VenueTalanta · 2024
Typearticle
Languageen
FieldChemistry
TopicAnalytical chemistry methods development
Canadian institutionsUniversity of Waterloo
FundersNatural Sciences and Engineering Research Council of CanadaCanada Research Chairs
KeywordsPolydimethylsiloxaneChemistryMembraneExtraction (chemistry)Solid-phase microextractionDivinylbenzeneGrapheneSorbentTap waterPolymerDesorptionOxideChemical engineeringDetection limitChromatographyAdsorptionStyreneMass spectrometryCopolymerGas chromatography–mass spectrometryOrganic chemistry

Abstract

fetched live from OpenAlex

Experimental and theoretical assessments of a graphene oxide-based polymer as adsorbent for thin film microextraction (TFME) were conducted as part of this research. Graphene oxide (GO) was embedded in the organic polymer poly(styrene-co-divinylbenzene) (PS-DVB) to prepare a sorbent suitable for direct-immersion TFME. A TFME membrane coating prepared with the GO/PS-DVB sorbent and polydimethylsiloxane (PDMS) as binder was then applied for extraction of organic pollutants from aqueous and gaseous samples. The surface morphology of the TFME coating was examined by scanning electron microscopy (SEM). Various TFME parameters influencing extraction efficiency, such as extraction time and temperature, desorption temperature, and ionic strength, were investigated and optimized. In a comparison of TFME membranes, the GO/PS-DVB/PDMS TFME membrane was shown to yield higher extraction efficiencies for the targeted analytes than the pure PDMS and DVB/PDMS TFME membranes. The calibration graphs of the organic pollutants displayed linearity for most of the target analytes within the 10–2000 ng L−1 concentration range. The repeatability (RSD %, n = 5) and reproducibility (RSD %, n = 3) of the method were in the ranges of 2.2–5.9 %, and 3.2–8.5 %, respectively, at a concentration level of 500 ng L−1, whereas accuracy (%) ranged between 79.8 and 119 %. The developed method was successfully applied for determinations of organic pollutants in tap water, lake water, and wastewater samples. Furthermore, the impact of mass transfer kinetics on extractions by the GO/PS-DVB/PDMS TFME membrane from gaseous samples was theoretically discussed and experimentally verified. The results of this work demonstrate that the GO/PS-DVB/PDMS TFME method is a simple, efficient, and environmentally friendly method for pre-treatment of organic pollutants.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.315
Teacher spread0.291 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueTalantaSame topicAnalytical chemistry methods developmentFrench-language works237,207