MétaCan
Menu
Back to cohort

Prevention of submicron aerosolized particle dispersion: evaluation of an aerosol box using a pediatric simulation model

2022· dataset· en· W4394297961 on OpenAlexaff
Laurence Tabone, Dominic Rivest, Arielle Lévy, Michael Buyck, Philippe Jouvet, Carl‐Éric Aubin, Tine François, Étienne Robert, Florent Baudin

Bibliographic record

VenueFigshare · 2022
Typedataset
Languageen
FieldMedicine
TopicInhalation and Respiratory Drug Delivery
Canadian institutionsUniversité de MontréalCentre Hospitalier Universitaire Sainte-Justine
Fundersnot available
KeywordsAerosolizationAerosolDispersion (optics)Particle (ecology)Environmental scienceMaterials scienceMeteorologyMedicinePhysicsOpticsGeologyInhalationAnesthesia

Abstract

fetched live from OpenAlex

Background and Aim: The SplashGuard CG (SG) is a barrier enclosure developed to protect healthcare workers from SARS-CoV-2 transmission during aerosol-generating procedures. Our objective was to evaluate the protection provided by the SG against aerosolized particles (AP), using a pediatric simulation model of spontaneous ventilation (SV) and noninvasive ventilation (NIV). Methods: An aerosol generator was connected to the airways of a pediatric high-fidelity manikin with a breathing simulator. AP concentrations were measured both in SV and NIV in the following conditions: with and without SG, inside and outside the SG, with and without suction applied to the device. Results: In the SV simulated setting, AP peaks were lower with SG: 0.1 × 105 particles/L compared to without: 1.6 × 105, only when the ports were closed and suction applied. In the NIV simulated setting, AP peaks outside the SG were lower than without SG (20.5 × 105 particles/L), whatever the situation, without suction (14.4 × 105particles/L), with suction and ports open or closed: 10.3 and 0.7 × 105 particles/L. In SV and NIV simulated settings, the AP peaks measured within the SG were much higher than the AP peaks measured without SG, even when suction was applied to the device. Conclusions: The SG seems to decrease peak AP exposure in the 2 ventilation contexts, but only with closed port and suction in SV. However, high concentrations of AP remain inside even with suction and SG should be used cautiously.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Dataset · Consensus signal: none
Teacher disagreement score0.010
Threshold uncertainty score0.019

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.142
GPT teacher head0.383
Teacher spread0.241 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreDataset

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueFigshareSame topicInhalation and Respiratory Drug DeliveryFrench-language works237,207