MétaCan
Menu
Back to cohort
Record W4394623447 · doi:10.52198/24.sti.44.os1759

Evaluation of an Initial Robotic-Assisted Direct Anterior Approach Cohort Receiving a New Short Metaphyseal Filling Collared Femoral Implant

2024· article· en· W4394623447 on OpenAlexaboutno aff
Joshua P Rainey, Jeremy M. Gililland, Kevin Marchand, Kelly Taylor, Michael A. Mont, Robert Marchand

Bibliographic record

VenueSurgical Technology Online · 2024
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsnot available
Fundersnot available
KeywordsCalcarMedicinePeriprostheticSurgeryImplantRadiographySurgical planningRadiologyArthroplasty

Abstract

fetched live from OpenAlex

BACKGROUND: Shorter, metaphyseal-filling collared stems have become popular with the direct anterior approach (DAA), based on their ease of broaching and insertion through less invasive surgical exposures. To aid with the DAA, robotic-assisted technology provides three-dimensional computed tomography (CT) preoperative planning and intraoperative guidance to accurately assess stem version. With other femoral stems, this has been shown to provide more accurate implant planning and improved patient outcomes. The purpose of this study was to understand femoral stem placement predictability and patient outcomes for a newly designed metaphyseal-filling collared stem system through a DAA in combination with a robotic-assisted system during a single surgeon's initial cases. MATERIALS AND METHODS: A single high-volume surgeon, experienced with robotic-assisted DAA total hip arthroplasty (THA), adopted the use of a metaphyseal-filling collared stem. Intraoperative data and patient outcomes up to six months postoperative were collected prospectively during the surgeon's first 123 cases. Student's t-tests (α=0.05) were used for statistical comparisons. Intraoperative and radiographic assessments were performed for all 123 cases. RESULTS: The estimated version with neck-cut view of the robotic-assisted system was 13.81 ± 3.81°. The final version measurement captured with the robotic-assisted system was 16.56 ± 6.61°. The difference between the estimated version and robotic-assisted measured version was, on average, 2.68 ± 5.7° (p<0.001). The femoral stem sat at the level of the calcar in all but five cases. There were no intraoperative or postoperative periprosthetic fractures. Patients reported significant improvements in reduced Hip dysfunction and Osteoarthritis Outcome Score for Joint Replacement (HOOS-JR), Patient-Reported Outcomes Measurement Information System (PROMIS 10), and Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores throughout their six-month recovery process with no patients reporting a periprosthetic joint infection, fracture, or dislocation. CONCLUSION: The use of a metaphyseal-filling collared stem with robotic-assisted DAA resulted in adequate stem version when assessed visually and with CT scan assessments. Version estimation values were improved upon over visual assessments when using the robotic system that maps out the proximal femur and the improvement was also demonstrated when compared to the prior literature. This may also be related to the stem's collar providing a visual guide during stem placement posterior fill of this triple-tapered stem design. Although further follow up is needed to assess longer-term outcomes, at six months postoperatively, patients had significant improvements in patient-reported outcomes with all patients reporting minimal to no restrictions with their THA.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.971
Threshold uncertainty score0.862

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.057
GPT teacher head0.359
Teacher spread0.302 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueSurgical Technology OnlineSame topicOrthopaedic implants and arthroplastyFrench-language works237,207