MétaCan
Menu
Back to cohort
Record W4394994958 · doi:10.1109/tbme.2024.3392333

MRI Accurately Visualizes RF Ablation Delivery Targeted to MRI-Defined Arrhythmia Substrates in the Left Ventricle

2024· article· en· W4394994958 on OpenAlexafffund
Philippa Krahn, Terenz Escartin, Sheldon M. Singh, Jennifer Barry, Melissa Larsen, Fumin Guo, Mihaela Pop, Graham A. Wright

Bibliographic record

VenueIEEE Transactions on Biomedical Engineering · 2024
Typearticle
Languageen
FieldMedicine
TopicCardiac Arrhythmias and Treatments
Canadian institutionsHealth Sciences CentreSunnybrook Health Science CentreSunnybrook HospitalUniversity of Toronto
FundersCanadian Institutes of Health ResearchGE Healthcare
KeywordsVentricleRadiofrequency ablationAblationRf ablationMagnetic resonance imagingMedicineReal-time MRIRadiologyCatheter ablationCardiologyBiomedical engineeringInternal medicine

Abstract

fetched live from OpenAlex

OBJECTIVE: Investigate the capacity of MRI to evaluate efficacy of radiofrequency (RF) ablations delivered to MRI-defined arrhythmogenic substrates. METHODS: Baseline MRI was performed at 3 T including 3D LGE in a swine model of chronic myocardial infarct (N = 8). MRI-derived maps of scar and heterogeneous tissue channels (HTCs) were generated using ADAS 3D. Animals underwent electroanatomic mapping and ablation of the left ventricle in CARTO3, guided by MRI-derived scar maps. Post-ablation MRI (in vivo at 3 T in 5/8 animals; ex vivo at 1.5 T in 3/8) included 3D native T1-weighted IR-SPGR (TI = 700-800 ms) to visualize RF lesions. T1-derived RF lesions were compared against excised tissue. The locations of T1-derived RF lesions were compared against CARTO ablation tags, and segment-wise sensitivity and specificity of lesion detection were calculated within the AHA 17-segment model. RESULTS: RF lesions were clearly visualized in HTCs, scar, and myocardium. Ablation patterns delivered in CARTO matched T1-derived RF lesion patterns with high sensitivity (88.9%) and specificity (94.7%), and were closely matched in registered MR-EP data sets, with a displacement of 5.4 ±3.8 mm (N = 152 ablation tags). CONCLUSION: Integrating MRI into ablative procedures for RF lesion assessment is feasible. Patterns of RF lesions created using a standard 3D EAM system are accurately reflected by MRI visualization in healthy myocardium, scar, and HTCs comprising the MRI-defined arrhythmia substrate. SIGNIFICANCE: MRI visualization of RF lesions can provide near-immediate ( 24 h) assessment of ablation, potentially indicating whether critical MRI-defined ventricular tachycardia substrates have been adequately ablated.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.341
Threshold uncertainty score0.639

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.279
Teacher spread0.263 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Transactions on Biomedical EngineeringSame topicCardiac Arrhythmias and TreatmentsFrench-language works237,207