International circumpolar surveillance: update on the interlaboratory quality control program for <i>Streptococcus pneumoniae</i> , 2009 to 2020
Bibliographic record
Abstract
ABSTRACT The International Circumpolar Surveillance (ICS) program is a population-based surveillance network for invasive bacterial diseases throughout Arctic countries and territories. The ICS quality control program for Streptococcus pneumoniae serotyping and antimicrobial susceptibility testing has been ongoing since 1999. Current participating laboratories include the Provincial Laboratory for Public Health in Edmonton, Alberta; Laboratoire de santé publique du Québec in Sainte-Anne-de-Bellevue, Québec; the Centers for Disease Control’s Arctic Investigations Program in Anchorage, Alaska; the Neisseria and Streptococcus Reference Laboratory at Statens Serum Institut in Copenhagen, Denmark; the Department of Clinical Microbiology, Landspitali in Reykjavik, Iceland; and Public Health Agency of Canada’s National Microbiology Laboratory in Winnipeg, Manitoba. From 2009 to 2020, 140 isolates of S. pneumoniae were distributed among the six laboratories as part of the quality control program. Overall serotype concordance was 96.9%, with 99.3% concordance to pool level. All participating laboratories had individual concordance rates >92% for serotype and >97% for pool. Overall concordance by modal minimum inhibitory concentration (MIC) for testing done by broth microdilution or Etest was 99.1%, and >98% for all antimicrobials tested. Categorical concordance was >98% by both CLSI and EUCAST criteria. For two laboratories performing disc diffusion, rates of concordance by modal MIC were >97% for most antimicrobials, except chloramphenicol (>93%) and trimethoprim/sulfamethoxazole (>88%). Data collected from 12 years of the ICS quality control program for S. pneumoniae demonstrate excellent (≥95%) overall concordance for serotype and antimicrobial susceptibility testing results across six laboratories. IMPORTANCE Arctic populations experience several social and physical challenges that lead to the increased spread and incidence of invasive diseases. The International Circumpolar Surveillance (ICS) program was developed to monitor five invasive bacterial diseases in Arctic countries and territories. Each ICS organism has a corresponding interlaboratory quality control (QC) program for laboratory-based typing, to ensure the technical precision and accuracy of reference testing services for these regions, and identify and correct potential problems. Here, we describe the results of the ICS Streptococcus pneumoniae QC program, from 2009 to 2020. Excellent overall concordance was achieved for serotype and antimicrobial susceptibility testing results across six laboratories. Ongoing participation in these QC programs ensures the continuation of quality surveillance systems within Arctic populations that experience health disparities.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".