MétaCan
Menu
Back to cohort
Record W4395116359 · doi:10.3389/fneur.2024.1366227

Testing of symmetric biphasic stimulation in Vim-DBS ET patients: a randomized-controlled pilot study

2024· article· en· W4395116359 on OpenAlexaboutno aff
Alexandra Boogers, Jana Peeters, Tine Van Bogaert, Philippe De Vloo, Wim P. Vandenberghe, Bart Nuttin, Myles Mc Laughlin

Bibliographic record

VenueFrontiers in Neurology · 2024
Typearticle
Languageen
FieldMedicine
TopicNeurological disorders and treatments
Canadian institutionsnot available
FundersEIT HealthAgentschap Innoveren en OndernemenBoston Scientific Corporation
KeywordsAtaxiaStimulationAdverse effectMedicineRandomized controlled trialRating scaleAudiologyQuality of life (healthcare)AnesthesiaPsychologyInternal medicineDevelopmental psychologyPsychiatry

Abstract

fetched live from OpenAlex

Introduction: Symmetric biphasic pulses have been shown to increase the therapeutic window compared to standard cathodic pulses in ET Vim-DBS patients. Furthermore, three hours of stimulation with biphasic pulses caused less stimulation-induced ataxia compared to cathodic pulses. Therefore, an investigation of the longer-term safety of biphasic pulses is warranted. Methods: Seven ET patients were included in a randomized double-blind, cross-over design of one week home-use of symmetric biphasic stimulation (anodic phase first) versus cathodic stimulation. Amplitude was set in a double-blinded way, at the tremor arrest threshold. The primary outcome was safety assessed by documenting the adverse events. Secondary outcome parameters were stimulation amplitude, tremor (Fahn-Tolosa-Marin Tremor Rating Scale) and ataxia (International Cooperative Ataxia Rating Scale) severity, quality of life (Quality of Life in Essential Tremor Questionnaire) and cognition (Montreal Cognitive Assessment). Three patients continued in the open-label extension phase for 3 months, during which biphasic stimulation-only was further assessed by the same outcome parameters. Results: = 0.003). The other outcome parameters were not significantly different. During the open-label study, one patient used the remote control to increase the amplitude, leading to two falls caused by stimulation-induced ataxia. No other adverse effects occurred. Discussion and conclusion: In a small cohort, when tested for one week, symmetric biphasic pulses suggest to be safe, but require higher stimulation amplitudes. Further follow-up studies are needed to investigate long-term effects and safety.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.019

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0060.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.283
Teacher spread0.262 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueFrontiers in NeurologySame topicNeurological disorders and treatmentsFrench-language works237,207