Calibrated intraoral scan protocol (<scp>CISP</scp>) for full‐arch implant impressions: An in vitro comparison to conventional impression, intraoral scan, and intraoral scan with scan‐aid

2024· article· en· W4396937984 on OpenAlexvenueno aff
Junying Li, Zhaozhao Chen, Paolo Nava, Shengtao Yang, Javier Calatrava, Hom‐Lay Wang

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2024
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsImpressionScannerImplantNuclear medicineDentistryMedicineOrthodonticsDental implantBiomedical engineeringComputer scienceSurgeryArtificial intelligence

Abstract

fetched live from OpenAlex

OBJECTIVE: To assess a newly developed intraoral scan protocol in enhancing the accuracy of complete-arch implant impressions. MATERIALS AND METHODS: Four impression approaches were applied to the same maxillary edentulous model with 6 implants: (1) intraoral scan (IOS), (2) intraoral scan with scan aid (IOS-SA), (3) calibrated intraoral scan protocol (CISP), and (4) conventional splinted open-tray impression (CONV). Each approach was repeated 10 times, and a direct scan of the model with a desktop scanner was used as a reference model. The alignment of scans and the reference model was conducted by two methods: (a) aligning all scan bodies to evaluate the overall fit, and (b) aligning the first and second scan bodies to simulate the Sheffield fit test for passive fitting of multiple implant-supported prostheses. Linear deviations from the reference model (trueness) and within each group (precision) were analyzed using Python scripts. RESULTS: When aligned by all scan bodies, the CISP group exhibited comparable mean trueness (38.33 μm) and precision (45.97 μm) to the CONV group (44.30 and 47.92 μm respectively), both of which significantly outperformed the IOS group (86.82 and 83.17 μm, respectively). Furthermore, in the virtual Sheffield fit test, the CISP group achieved the highest levels of mean trueness at the end span (121.7 μm), making a linear deviation reduction of 36.7%, 60%, and 41.4% when compared to the CONV, the IOS, and the IOS-SA groups, respectively. Moreover, the CISP group (104.3 μm) displayed a remarkable 65, 182, and 86 μm advantage in precision over the CONV, IOS, and IOS-SA groups, respectively. CONCLUSION: CISP demonstrated comparable accuracy to the gold standard, the conventional splinted open-tray impression. Furthermore, it excelled in the virtual passive fitting test.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.113
GPT teacher head0.494
Teacher spread0.381 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→