MétaCan
Menu
Back to cohort
Record W4397040524 · doi:10.1111/opo.13332

Suitability of multifunction devices Myah and Myopia Master for monitoring myopia progression in children and adults

2024· article· en· W4397040524 on OpenAlex
Amy Chow, Melanie Mungalsingh, Danny Thai, Zoe Selimos, Sarah Kathryn Yan, Hellen Xu, Deborah Jones

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueOphthalmic and Physiological Optics · 2024
Typearticle
Languageen
FieldMedicine
TopicOphthalmology and Visual Impairment Studies
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsRepeatabilityReproducibilityIntraclass correlationCycloplegiaLimits of agreementMedicineOptometryStandard deviationOphthalmologyRefractive errorMathematicsNuclear medicineEye diseaseStatistics

Abstract

fetched live from OpenAlex

PURPOSE: To assess the feasibility of using multifunction instruments to measure axial length for monitoring myopia progression in children and adults. METHODS: Axial length was measured in 60 children (aged 6-18 years) and 60 adults (aged 19-50 years) with multifunction instruments (Myah and Myopia Master) and stand-alone biometers (Lenstar LS900 and IOLMaster 700). Repeatability (measurements by the same examiner) and reproducibility (measurements by different examiners) were computed as the within-subject standard deviation (Sw) and 95% limits of agreement (LoA). Inter-instrument agreement was computed as intraclass correlation coefficients. The threshold for detecting myopic progression was taken as 0.1 mm. Measures were repeated only in children following the administration of 1% tropicamide to determine the impact of cycloplegia on axial length. RESULTS: Overall, the IOLMaster 700 had the best repeatability in children (0.014 mm) and adults (0.009 mm). Repeatability Sw values for all devices ranged from 0.005 to 0.021 mm (children) and 0.003 to 0.016 mm (adults). In children, reproducibility fell within 0.1 mm 95% of the time for the Myah, Myopia Master and IOLMaster 700. Agreement among all devices was classified as excellent (ICC 0.999; 95% CI 0.998-0.999), but the 95% LoA among the Myah, Myopia Master and Lenstar LS900 was ≥0.1 mm. Cycloplegia had no statistically significant effect on axial length (all p > 0.13). CONCLUSIONS: The Myah and Myopia Master multifunction instruments demonstrated good repeatability and reproducibility, and their accuracy was comparable to stand-alone biometers. Axial length measurements using different instruments can be considered interchangeable but should be compared with some caution. Accurate axial length measurements can be obtained without cycloplegia. The multifunction instruments Myah and Myopia Master are as well suited for monitoring myopia progression in children as the stand-alone biometers IOLMaster 700 and Lenstar LS900.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score0.358

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.051
GPT teacher head0.365
Teacher spread0.314 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it