MétaCan
Menu
Back to cohort

Label-free electrochemical detection of glycated hemoglobin (HbA1c) and C-reactive protein (CRP) to predict the maturation of coronary heart disease due to diabetes

2024· article· en· W4397289343 on OpenAlex
Rehmat Grewal, Greter A. Ortega, Fei Geng, Seshasai Srinivasan, Amin Reza Rajabzadeh

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueBioelectrochemistry · 2024
Typearticle
Languageen
FieldEngineering
TopicElectrochemical sensors and biosensors
Canadian institutionsMcMaster University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsGlycated hemoglobinDiabetes mellitusC-reactive proteinHemoglobinCoronary heart diseaseDetection limitInternal medicineBiomarkerElectrochemistryMedicineType 2 diabetesGlycated haemoglobinLinear rangeCardiologyChemistryEndocrinologyChromatographyInflammationBiochemistryElectrode

Abstract

fetched live from OpenAlex

The pathophysiological link between diabetes and heightened propensity for the development of coronary heart disease (CHD) is well-established. Prevailing evidence confirms that small increases in low concentrations of high-sensitivity C reactive protein (hs-CRP) in the human body can determine the tendency of developing CHD. Additionally, glycated hemoglobin (HbA1c) is a well-recognized biomarker to evaluate diabetes progression. Given the positive correlation between diabetes and CHD, this research presents a notably unprecedented label-free electrochemical approach for the dual detection of %HbA1c regarding Total Hb and hs-CRP, facilitating early CHD prediction and cost-effective point-of-care diagnostics. Furthermore, a novel redox probe O-(4-Nitrophenylphosphoryl)choline (C11H17N2O6P) was used for the electrochemical detection of CRP, a method not documented in scientific literature before. The calibration curves demonstrate a limit of detection (LOD) of 5 mg/mL in PBS (pH 8) and 6 mg/mL in simulated blood (SB) for a linear range of 0–30 mg/mL of HbA1c. Conjointly, a LOD of 0.007 mg/mL and 0.008 mg/mL for measurement in PBS (pH 7.4) and SB are reported for a linear range of 0–0.05 mg/mL of CRP. The electrochemical systems presented could accurately quantify HbA1c and CRP in mixed samples, demonstrating reasonable specificity and practical applicability for complex biological samples.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.873

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.003
GPT teacher head0.187
Teacher spread0.184 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it