MétaCan
Menu
Back to cohort
Record W4398141840 · doi:10.1002/mp.17133

Investigation of dosimetric characteristics of radiochromic film in response to alpha particles emitted from Americium‐241

2024· article· en· W4398141840 on OpenAlexafffund
Víctor D. Díaz-Martínez, Mélodie Cyr, Slobodan Dević, Nada Tomic, David F. Lewis, Shirin A. Enger

Bibliographic record

VenueMedical Physics · 2024
Typearticle
Languageen
FieldEngineering
TopicNuclear reactor physics and engineering
Canadian institutionsMcGill University Health CentreJewish General HospitalMcGill University
FundersCanada First Research Excellence FundConsejo Nacional de Ciencia y TecnologíaCanada Research Chairs
KeywordsAmericiumAlpha particleAlpha (finance)RadiochemistryDosimetryMaterials scienceMedical physicsNuclear physicsNuclear medicinePhysicsMedicineActinideChemistryClinical psychology

Abstract

fetched live from OpenAlex

Abstract Background In radiotherapy, it is essential to deliver prescribed doses to tumors while minimizing damage to surrounding healthy tissue. Accurate measurements of absorbed dose are required for this purpose. Gafchromic® external beam therapy (EBT) radiochromic films have been widely used in radiotherapy. While the dosimetric characteristics of the EBT3 model film have been extensively studied for photon and charged particle beams (protons, electrons, and carbon ions), little research has been done on ‐particle dosimetry. ‐emitting radionuclides have gained popularity in cancer treatment due to their high linear energy transfer, short range in tissue, and ability to spare surrounding organs at risk, thereby delivering a more localized dose distribution to the tumor. Therefore, a dose‐calibration film protocol for ‐particles is required. Purpose This study aimed to develop a dose‐calibration protocol for the ‐particle emitting radionuclide 241Am, using Monte Carlo (MC) simulations and measurements with unlaminated EBT3 films. Methods In this study, a MC‐based user code was developed using the Geant4 simulation toolkit to model and simulate an 241Am source and an unlaminated EBT3 film. Two simulations were performed: one with voxelized geometries of the EBT3 active volume composition and the other using water. The dose rate was calculated within a region of interest in the voxelized geometries. Unlaminated EBT3 film pieces were irradiated with the 241Am source at various exposure times inside a black box. Film irradiations were compared to a 6‐MV photon beam from a Varian TrueBeam machine. The simulated dose rate was used to convert the exposure times into absorbed doses to water, describing a radiochromic‐film‐based reference dosimetry protocol for ‐particles. The irradiated films were scanned and through an in‐house Python script, the normalized pixel values from the green‐color channel of scanned film images were analyzed. Results The 241Am energy spectra obtained from the simulations were in good agreement with IAEA and NIST databases, having differences 0.516% for the emitted ‐rays and produced characteristic x‐rays and 0.006% for the ‐particles. Due to the short range of ‐particles, there was no energy deposition in the voxels outside the active 241Am source region projected onto the film surface. Thus, the total dose rate within the voxels covering the source was 0.847 0.003 Gy/min within the sensitive layer of the film (LiPCDA) and 0.847 0.004 Gy/min in water, indicating that the active volume can be considered water equivalent for the 241Am beam quality. A novel approach was employed in ‐film dosimetry using an exponential fit for the green channel, which showed promising results by reducing the uncertainty in dose estimation within 5%. Although the statistical analysis did not reveal significant differences between the 6‐MV photon beam and the calibration curves, the dose–response curves exhibited the expected behavior. Conclusions The developed MC user code simulated the experimental setup for ‐dosimetry using radiochromic film with acceptable uncertainty. Unlaminated EBT3 film is suitable for the dosimetry of ‐radiation at low doses and can be used in conjunction with other unlaminated GafChromic® films for quality assurance and research purposes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.214
Teacher spread0.204 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicNuclear reactor physics and engineeringFrench-language works237,207