Risk factors for thromboembolic events in pediatric patients with ventricular assist devices

2024· article· en· W4398784896 on OpenAlexafffund
J Adderley, Tara Pidborochynski, Holger Buchholz, Paula Holinski, Vijay Anand, Izak De Villiers Jonker, Darren H. Freed, Mohammed Al‐Aklabi, Jennifer Conway

Bibliographic record

VenueJTCVS Open · 2024
Typearticle
Languageen
FieldEngineering
TopicMechanical Circulatory Support Devices
Canadian institutionsStollery Children's HospitalUniversity of Alberta
FundersAlberta Innovates
KeywordsCardiologyMedicineInternal medicineIntensive care medicine

Abstract

fetched live from OpenAlex

Objective Pediatric patients on ventricular assist devices (VAD) are at risk of thromboembolic (TE) complications. Our objective was to identify factors associated with TE events, including the role of initial anticoagulation strategy and device type in the pediatric VAD population. Methods This was a retrospective, single-center review (2005-2022) of children who were implanted with paracorporeal pulsatile (PP), paracorporeal continuous (PC), or a combination of devices. Patient- and device-related factors were collected. Kaplan-Meier survival analysis was performed to determine freedom from TE. Cox proportional hazard analysis was conducted to look for factors associated with TE events. Results Ninety-five patients included with a median age of 0.9 years (interquartile range, 0.3, 5.4); median weight of 8.4 kg (interquartile range, 4.5, 17.8), and 63.2% with noncongenital heart disease. Device breakdown included 47.4% PC, 24.2% PP, and 23.2% combination of devices. Initial anticoagulation was either heparin (61.5%) or bivalirudin (38.5%). In Kaplan-Meier analysis, unadjusted freedom from a TE event was significantly greater in those who received bivalirudin as their initial anticoagulation strategy ( P = .02) and PP VADs ( P = .02). In multivariate analysis, initial anticoagulation strategy with bivalirudin (hazard ratio, 0.30; 95% confidence interval, 0.12-0.75, P = .01) was associated with a reduced hazard of TE events, whereas PC device strategy was found to be associated with an increased hazard (hazard ratio, 2.78; 95% confidence interval, 1.12-6.88, P = .03). Conclusions This study suggests that PC device strategy and heparin as an initial anticoagulation strategy are associated with increased hazard of TE events. Further research is required to understand the interaction between device type and initial anticoagulation strategy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.251
Teacher spread0.236 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueJTCVS OpenSame topicMechanical Circulatory Support DevicesFrench-language works237,207