MétaCan
Menu
Back to cohort
Record W4399570241 · doi:10.1186/s44348-024-00001-w

Two-dimensional transthoracic measure of mitral annulus in mitral valve prolapse and moderate to severe regurgitation: a method comparison analysis with three-dimensional transesophageal echocardiography

2024· article· en· W4399570241 on OpenAlexaff
Maxime Berthelot‐Richer, Halyna Viktorivna Vakulenko, Anna Calleja, Anna Woo, Paaladinesh Thavendiranathan, Frédéric Poulin

Bibliographic record

VenueJournal of Cardiovascular Imaging · 2024
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsUniversity of TorontoToronto General HospitalUniversité de MontréalHôpital du Sacré-Cœur de Montréal
Fundersnot available
KeywordsMedicineMitral regurgitationMitral annulusCardiologyInternal medicineMitral valveMitral valve prolapseRegurgitation (circulation)Annulus (botany)Blood pressureDiastole

Abstract

fetched live from OpenAlex

Abstract Background Mitral annulus (MA) area is derived during transthoracic echocardiography (TTE) assuming of a circular shape using the MA diameter from the apical 4 chamber (A4c) view. Since the MA is not a circular structure, we hypothesized that an elliptical model using parasternal long-axis (PLAX) and apical 2 chamber (A2c) view measured MA diameters would have better agreement with 3-dimensional transesophageal echocardiography (3D TEE) measured MA in degenerative mitral valve disease (DMVD). Methods Seventy-six patients with moderate-to-severe DMVD had 2D TTE and 3D TEE performed. MA area was measured retrospectively using semi-automatic modeling of 3D data (3D TEE sa ) and considered as the reference method. MA diameters were measured using different 2D TTE views. MA area was calculated using assumptions of a circular or an elliptical shape. 2D TTE derived and 3D TEE sa . MA areas were compared using linear regression and Bland-Altman analysis. Results The median MA area measured at 3D TEE sa was 1,386 (1,293–1,673) mm 2 . With 2D TTE, the circular model using A4c view diameter resulted in a small systematic underestimation of MA area (6%), while the elliptical model using PLAX and A2c diameters resulted in 25% systematic underestimation. The standard deviations of the distributions of inter-method differences were wide for all 2D TTE methods (265–289 mm 2 ) when compared to 3D TEE sa , indicating imprecision. Conclusions When compared with 3D TEE sa modeling of the MA as the reference, the assumption of a circular shape using A4c TTE view diameter was the method with the least systematic error to assess MA area in DMVD and moderate to severe regurgitation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Meta-epidemiology (broad)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.512
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0020.012
Bibliometrics0.0010.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.321
Teacher spread0.310 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Cardiovascular ImagingSame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207