A recommendation for the use of electrical biosensing technology in neonatology

2024· article· en· W4400422058 on OpenAlexaff
Lizelle van Wyk, Topun Austin, Bernard Barzilay, María Carmen Bravo, Morten Breindahl, Christoph Czernik, Eugene Dempsey, Willem P. de Boode, Willem de Vries, Beate Horsberg Eriksen, Jean‐Claude Fauchère, Elisabeth M. W. Kooi, Philip T. Levy, Patrick J. McNamara, Subhabrata Mitra, Eirik Nestaas, Heike Rabe, Yacov Rabi, Sheryle Rogerson, Marilena Savoia, Frederico Schena, Arvind Sehgal, Christoph E. Schwarz, Ulrich Thomé, David Van Laere, Gabriela Zaharie, Samir Gupta

Bibliographic record

VenuePediatric Research · 2024
Typearticle
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsUniversity of Calgary
Fundersnot available
KeywordsNeonatologyMedicineHemodynamicsStroke volumeIntensive care medicineCardiac outputCardiologyInternal medicineHeart rate

Abstract

fetched live from OpenAlex

Non-invasive cardiac output monitoring, via electrical biosensing technology (EBT), provides continuous, multi-parameter hemodynamic variable monitoring which may allow for timely identification of hemodynamic instability in some neonates, providing an opportunity for early intervention that may improve neonatal outcomes. EBT encompasses thoracic (TEBT) and whole body (WBEBT) methods. Despite the lack of relative accuracy of these technologies, as compared to transthoracic echocardiography, the use of these technologies in neonatology, both in the research and clinical arena, have increased dramatically over the last 30 years. The European Society of Pediatric Research Special Interest Group in Non-Invasive Cardiac Output Monitoring, a group of experienced neonatologists in the field of EBT, deemed it appropriate to provide recommendations for the use of TEBT and WBEBT in the field of neonatology. Although TEBT is not an accurate determinant of cardiac output or stroke volume, it may be useful for monitoring longitudinal changes of hemodynamic parameters. Few recommendations can be made for the use of TEBT in common neonatal clinical conditions. It is recommended not to use WBEBT to monitor cardiac output. The differences in technologies, study methodologies and data reporting should be addressed in ongoing research prior to introducing EBT into routine practice. IMPACT STATEMENT: TEBT is not recommended as an accurate determinant of cardiac output (CO) (or stroke volume (SV)). TEBT may be useful for monitoring longitudinal changes from baseline of hemodynamic parameters on an individual patient basis. TEBT-derived thoracic fluid content (TFC) longitudinal changes from baseline may be useful in monitoring progress in respiratory disorders and circulatory conditions affecting intrathoracic fluid volume. Currently there is insufficient evidence to make any recommendations regarding the use of WBEBT for CO monitoring in neonates. Further research is required in all areas prior to the implementation of these monitors into routine clinical practice.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.928
Threshold uncertainty score0.208

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.251
GPT teacher head0.474
Teacher spread0.223 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2024
Admission routes1
Has abstractyes

Explore more

Same venuePediatric ResearchSame topicHemodynamic Monitoring and TherapyFrench-language works237,207