Effects of Implantable Cardioverter-Defibrillator Leads on the Tricuspid Valve and Right Ventricle
Bibliographic record
Abstract
BACKGROUND: There are no randomized data to inform the extent to which transvenous cardiac leads cause tricuspid regurgitation (TR). OBJECTIVES: This study sought to determine the effect of a transvenous implantable cardioverter-defibrillator (TV-ICD) on TR severity, and secondarily, on right ventricular (RV) size and function. METHODS: We evaluated TR severity before and 6 months after implantable cardioverter-defibrillator insertion in a post hoc analysis of adults randomized to receive a transvenous (n = 252) or subcutaneous implantable cardioverter-defibrillator (S-ICD) (n = 251) device. TR and RV size and systolic function were assessed by echocardiographic images analyzed in a core laboratory. RESULTS: At baseline, at least mild TR was present in 30% of individuals. At 6 months, the proportion of participants with any TR in the TV-ICD group was 42% vs 19% in the S-ICD group (P < 0.001). The proportion with moderate or severe TR was 7% in the TV-ICD group vs 2% in the S-ICD group (P = 0.021). At 6 months, the OR of at least 1 grade worsening of TR in the TV-ICD group as compared with the S-ICD group was 7.2 (95% CI: 3.3-15.8; P < 0.001). There were no differences between groups with respect to RV size or systolic function. CONCLUSIONS: Six months following TV-ICD insertion, there was a 7-fold increase in the risk of at least 1 grade worsening of TR, with 7% of individuals having TR that was moderate or severe. There was no detectable difference in RV size or function; however, longer follow-up is needed.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.002 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".