MétaCan
Menu
← Back to cohort
Record W4400495958 · doi:10.1002/ksa.12352

Femorotibial angle scan–rescan reproducibility: A high‐precision calculation on a large cohort

2024· article· en· W4400495958 on OpenAlexaboutno aff
Thomas A. Hall, Gareth G. Jones, Richard J. van Arkel

Bibliographic record

VenueKnee Surgery Sports Traumatology Arthroscopy · 2024
Typearticle
Languageen
FieldMedicine
TopicTotal Knee Arthroplasty Outcomes
Canadian institutionsnot available
FundersGlaxoSmithKlineNovartis Pharmaceuticals CorporationPfizerNational Institutes of HealthU.S. Department of Health and Human ServicesFoundation for the National Institutes of Health
KeywordsReproducibilityCoronal planeRadiographyOsteoarthritisMedicineNuclear medicineKappaOrthodonticsKnee JointCohortRadiologyMathematicsSurgeryInternal medicinePathologyStatistics

Abstract

fetched live from OpenAlex

Abstract Purpose Femorotibial angle (FTA) is a convenient measure of coronal knee alignment that can be extracted from a short knee radiograph, avoiding the additional radiation exposure and specialist equipment required for full‐leg radiographs. While intra‐ and inter‐reader reproducibility from the same image has been reported, the full scan–rescan reproducibility across images, as calculated in this study, has not. Methods In this study, 4589 FTA measurement pairs from 2586 subjects acquired a year apart were used to estimate FTA scan–rescan reproducibility using data from the Osteoarthritis Initiative. Subjects with radiographic progression of osteoarthritis or other conditions that may cause a change in coronal knee alignment were excluded. Measurement pairs were analysed using paired‐samples tests to detect differences and compared to symptomatic changes in Western Ontario and McMaster Universities Arthritis Index scores for joint pain, stiffness and physical function to detect correlations. Results The 95% limit of agreement and the paired‐samples correlation were calculated with high precision to be [−1.76°, +1.78°] and 0.938, considerably worse than the corresponding figures for intra‐ and inter‐reader reproducibility, without relation to symptomatic or radiographic changes in knee condition. This error will weakly attenuate and values from their true values in correlative studies involving FTA. The realistic maximum value for is 87% and for Pearson's is 93%. Conclusion The scan–rescan reproducibility in FTA is almost double the intra‐ and inter‐reader reliability from a single scan. At almost ±2° accuracy, FTA is inappropriate for surgical use, but it is sufficiently reproducible to produce good correlations in studies predicting disease incidence and progression. Level of Evidence Level II, retrospective study.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.018
metaresearch head score (Gemma)0.027
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.018
Threshold uncertainty score0.097

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0180.027
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.285
Teacher spread0.269 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueKnee Surgery Sports Traumatology Arthroscopy→Same topicTotal Knee Arthroplasty Outcomes→French-language works237,207→