MétaCan
Menu
Back to cohort
Record W4400646138 · doi:10.1016/j.bjps.2024.07.026

Utility of 3D-printed vascular modeling in microsurgical breast reconstruction: a systematic review

2024· review· en· W4400646138 on OpenAlexaffabout
Arashk Ghasroddashti, Colm Guyn, Glykeria Martou, Robert Edmunds

Bibliographic record

VenueJournal of Plastic Reconstructive & Aesthetic Surgery · 2024
Typereview
Languageen
FieldEngineering
TopicAnatomy and Medical Technology
Canadian institutionsUniversity of AlbertaQueen's University
Fundersnot available
Keywords3d printedBreast reconstructionComputer scienceBiomedical engineeringMedicineBreast cancerInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Microsurgical breast reconstruction presents a technical challenge in preoperative planning and flap harvest. Given the limitations of computed tomographic angiography as a preoperative aid, 3D printing has emerged as an avenue for creating patient-specific anatomical models for pre- and intraoperative use. This systematic review assesses the current use and utility of 3D-printed vascular models (3DVMs) in microsurgical breast reconstruction. METHODS: MEDLINE, Embase, and CENTRAL were searched for English articles published from 1946 to 2024. Studies utilizing 3D-printed vascular modeling in the context of microsurgical breast reconstruction were included if they reported surgical, model-, or user-related outcomes. The Newcastle-Ottawa Scale and Joanna Briggs Institute checklists were used for quality assessment. Results were reported according to PRISMA guidelines. RESULTS: Six hundred and nineteen records were retrieved. Following specific inclusion and exclusion criteria, 29 studies underwent full-text review. Eight studies totaling 181 patients and 261 flaps were included in the final analysis. 3DVMs were used to model deep inferior epigastric perforator (DIEP) and muscle-sparing transverse rectus abdominis myocutaneous (MS-TRAM) flap perforator origin, course, distribution, and surrounding anatomy. They were used for perforator selection, flap harvest, and training. Use of 3DVMs reduced harvest time by up to 23 min per case. No complications or preoperative plan deviations were reported in 3DVM-guided cases. Surgeons endorsed significant model utility in anatomical visualization, preoperative planning, and flap harvest. Model cost, production time, and adoption were identified as barriers to use. CONCLUSIONS: 3DVMs can enhance preoperative planning, intraoperative decision-making, and operative efficiency in unilateral DIEP and bilateral MS-TRAM flap breast reconstructions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.494
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0070.002
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.264
Teacher spread0.236 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Plastic Reconstructive & Aesthetic SurgerySame topicAnatomy and Medical TechnologyFrench-language works237,207