MétaCan
Menu
Back to cohort
Record W4400970077 · doi:10.1177/15910199241264345

Comparison of pipeline embolization device and flow redirection endoluminal device in the treatment of intracranial aneurysms: A systematic review and meta-analysis

2024· review· en· W4400970077 on OpenAlexaff
Basel Musmar, Atakan Orscelik, Hamza Salim, Fares Musmar, Nimer Adeeb, Kareem El Naamani, Muhammed Amir Essibayi, Samantha Spellicy, Jihad Abdelgadir, Adam A. Dmytriw, Aman B. Patel, Vítor Mendes Pereira, Hugo Cuellar, Bharat Guthikonda, Ali Zomorodi, Pascal Jabbour, David Hasan

Bibliographic record

VenueInterventional Neuroradiology · 2024
Typereview
Languageen
FieldMedicine
TopicIntracranial Aneurysms: Treatment and Complications
Canadian institutionsSt. Michael's Hospital
Fundersnot available
KeywordsMedicineEndovascular treatmentEmbolizationPipeline (software)Flow diverterMeta-analysisRadiologySurgeryAneurysmInternal medicineMechanical engineeringEngineering

Abstract

fetched live from OpenAlex

BACKGROUND: Advancements in flow diversion technology have revolutionized the treatment of intracranial aneurysms. The pipeline embolization device (PED) and the flow redirection endoluminal device (FRED) have emerged as prominent tools in this field. This study aims to compare the safety and efficacy profiles of PED and FRED in the treatment of intracranial aneurysms. METHODS: Following the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines, a comprehensive literature search was conducted across PubMed, Web of Science, and Scopus databases. Studies comparing PED and FRED were included and data extraction focused on study characteristics, patient demographics, and clinical and radiological outcomes. Primary outcomes were favorable outcomes, described as modified Rankin scale (mRS) 0-2 score, and complete/near-complete occlusion, while secondary outcomes included retreatment rate and thromboembolic and hemorrhagic complications. RESULTS: Five studies, comprising 1238 patients, were included. No significant differences were found between PED and FRED in terms of complete occlusion at 6 months and 1 year, complete/near-complete occlusion at the last follow up, retreatment rates, and thromboembolic, in-stent thrombosis and hemorrhagic complications. However, FRED was significantly associated with higher favorable outcomes compared to PED (odds ratio: 0.37; confidence interval: 0.17 to 0.81; p = 0.01). CONCLUSION: This study showed that both PED and FRED had comparable rates of complete occlusion, retreatment and complications, and FRED also demonstrated a higher likelihood of achieving favorable outcomes. The study underscores the need for further research with larger cohorts and longer follow up to consolidate these findings.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.924
Threshold uncertainty score0.919

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0060.002
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.130
GPT teacher head0.416
Teacher spread0.286 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueInterventional NeuroradiologySame topicIntracranial Aneurysms: Treatment and ComplicationsFrench-language works237,207