MétaCan
Menu
Back to cohort
Record W4401325629 · doi:10.1016/j.tipsro.2024.100267

Clinical implementation of real time motion management for prostate SBRT: A radiation therapist’s perspective

2024· article· en· W4401325629 on OpenAlexfundno aff
Joanne Mitchell, Duncan B. McLaren, Donna Burns Pollock, Joella Wright, Angus Killean, M. Trainer, S. Adamson, Laura McKernan, William H. Nailon

Bibliographic record

VenueTechnical Innovations & Patient Support in Radiation Oncology · 2024
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsnot available
FundersUniversity of EdinburghInstitute of GeneticsChristie CharityKingston University
KeywordsPerspective (graphical)Medical physicsMedicineMotion (physics)ProstateRadiologyComputer scienceComputer visionArtificial intelligenceInternal medicine

Abstract

fetched live from OpenAlex

Background and purpose: The adoption of hypo-fractionated stereotactic body radiotherapy (SBRT) for treating prostate cancer has led to an increase in specialised techniques for monitoring prostate motion. The aim of this study was to comprehensively review a radiation therapist (RTT) led treatment process in which two such systems were utilised, and present initial findings on their use within a SBRT prostate clinical trial. Materials and Methods: (HC) system. 36.25 Gray (Gy) was delivered in 5 fractions over 7 days with daily pre- and post-treatment cone beam computed tomography (CBCT) images acquired. Acute toxicity was reported on completion of treatment at six- and 12-weeks post-treatment, using the Radiation Therapy Oncology Group (RTOG) grading system and vertical (Vrt), longitudinal (Lng) and lateral (Lat) transmitter displacements recorded. Results: A significant difference was found in the Lat displacement between devices (P=0.003). A more consistent bladder volume was reported in the HC group (68.03 cc to 483.7 cc RP, 196.11 cc to 313.85 cc HC). No significant difference was observed in mean dose to the bladder, rectum and bladder dose maximum between the groups. Comparison of the rectal dose maximum between the groups reported a significant result (P=0.09). Comparing displacements with toxicity endpoints identified two significant correlations: Grade 2 Genitourinary (GU) at 6 weeks, P=0.029; and no toxicity, Gastrointestinal (GI) at 12 weeks P=0.013. Conclusion: Both the directly implanted RP device and the urinary catheter-based HC device are capable of real time motion monitoring. Here, the HC system was advantageous in the SBRT prostate workflow.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.758
Threshold uncertainty score0.772

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.415
Teacher spread0.396 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueTechnical Innovations & Patient Support in Radiation OncologySame topicAdvanced Radiotherapy TechniquesFrench-language works237,207