MétaCan
Menu
← Back to cohort

Inverse estimation of the annual heat flux through the internal surface of a multilayer wall in an occupied prefabricated house from field measurements

2024· article· en· W4401447281 on OpenAlexafffundabout
Nícolas Pinheiro Ramos, Leonardo Delgadillo Buenrostro, Sandro Metrevelle Marcondes de Lima e Silva, Louis Gosselin

Bibliographic record

VenueInternational Communications in Heat and Mass Transfer · 2024
Typearticle
Languageen
FieldEngineering
TopicBuilding Energy and Comfort Optimization
Canadian institutionsUniversité Laval
FundersFundação de Amparo à Pesquisa do Estado de Minas GeraisConselho Nacional de Desenvolvimento Científico e TecnológicoNatural Sciences and Engineering Research Council of CanadaCoordenação de Aperfeiçoamento de Pessoal de Nível Superior
KeywordsFlux (metallurgy)Heat fluxInverseMaterials scienceMechanicsField (mathematics)EstimationSurface (topology)Inverse methodMeteorologyEnvironmental scienceHeat transferPhysicsGeometryMathematics

Abstract

fetched live from OpenAlex

Understanding transient heat transfer in building assemblies is important for improving the energy efficiency of the built environment. This paper describes an inverse analysis to evaluate the field energy performance of a multilayer prefabricated wall. The purpose is to estimate the heat flux through the internal surface of a wall in an occupied lightweight house in Quebec City (Canada). The inverse problem modeling was based on one-year on-site temperature measurements which convey the in-use thermal behavior of the wall assembly. The inner surface experienced an outward heat flux for most of the year. The greatest heat loss was around 5.5 W m −2 in winter and the greatest heat gain was around 1.0 W m −2 in summer. In the heating period, the indoor environment lost about 18 kW h m −2 (6.5 × 10 7 J m −2 ) of thermal energy. There was a total thermal gain of around 1 kW h m −2 (3.5 × 10 6 J m −2 ) during the free cooling period. Based on the heat flux estimations, the effective thermal resistance of the assembly was found to be 6% lower than its theoretical value, but still in compliance with Canadian building standards.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.079
Threshold uncertainty score0.156

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.041
GPT teacher head0.286
Teacher spread0.245 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2024
Admission routes3
Has abstractyes

Explore more

Same venueInternational Communications in Heat and Mass Transfer→Same topicBuilding Energy and Comfort Optimization→French-language works237,207→